Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가

Full metadata record
DC Field Value Language
dc.contributor.author김총명-
dc.contributor.author전진훈-
dc.contributor.author김웅철-
dc.contributor.author이재준-
dc.contributor.author김지환-
dc.date.accessioned2021-09-04T07:13:03Z-
dc.date.available2021-09-04T07:13:03Z-
dc.date.created2021-06-17-
dc.date.issued2016-
dc.identifier.issn1229-3954-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/91006-
dc.description.abstractPurpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The RMS±SD value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were 28.5±4.1㎛ and 19.1±2.8㎛, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The RMS±SD value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were 14.9±1.9㎛ and 13.3±2.5㎛, respectively;and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한치과기공학회-
dc.title2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가-
dc.title.alternativePrecision evaluation of crown prosthesis manufactured by two bur and three bur-
dc.typeArticle-
dc.contributor.affiliatedAuthor김웅철-
dc.identifier.doi10.14347/kadt.2016.38.2.57-
dc.identifier.bibliographicCitation대한치과기공학회지, v.38, no.2, pp.57 - 62-
dc.relation.isPartOf대한치과기공학회지-
dc.citation.title대한치과기공학회지-
dc.citation.volume38-
dc.citation.number2-
dc.citation.startPage57-
dc.citation.endPage62-
dc.type.rimsART-
dc.identifier.kciidART002116625-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorDental CAD/CAM systems-
dc.subject.keywordAuthorMilling bur-
dc.subject.keywordAuthorMilling machine-
dc.subject.keywordAuthorPrecision-
dc.subject.keywordAuthorThree-dimensional evaluation-
dc.subject.keywordAuthor5-axis milling-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE