Seismic performance of a 10-story RC box-type wall building structure
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hwang, Kyung Ran | - |
dc.contributor.author | Lee, Han Seon | - |
dc.date.accessioned | 2021-09-04T09:58:26Z | - |
dc.date.available | 2021-09-04T09:58:26Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-12 | - |
dc.identifier.issn | 2092-7614 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/91692 | - |
dc.description.abstract | The purpose of this study is to evaluate the seismic performance of high-rise reinforced concrete (RC) box-type wall structures commonly used for most residential buildings in Korea. For this purpose, an analytical model was calibrated with the results of the earthquake simulation tests on a 1: 5 scale 10-story distorted model. This calibrated model was then transformed to a true model. The performance of the true model in terms of the stiffness, strength, and damage distribution through inelastic energy dissipation was observed with reference to the earthquake simulation test results. The model showed high overstrength factors ranging from 3 to 4. The existence of slab in this box-type wall system changed the main resistance mode in the wall from bending moment to tension/compression coupled moment through membrane actions, and increased the overall resistance capacity by about 25 similar to 35%, in comparison with the common design practice of neglecting the slab's existence. The flexibility of foundation, which is also commonly neglected in the engineering design, contributes to 30 similar to 50% of the roof drift in the stiff direction containing many walls. The possibility of concrete spalling and reinforcement buckling and fracture under the maximum considered earthquake (MCE) in Korea appears to be very low when compared with the case of the 2010 Concepcion, Chile earthquake. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | TECHNO-PRESS | - |
dc.subject | DESIGN | - |
dc.subject | BEHAVIOR | - |
dc.title | Seismic performance of a 10-story RC box-type wall building structure | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Han Seon | - |
dc.identifier.doi | 10.12989/eas.2015.9.6.1193 | - |
dc.identifier.scopusid | 2-s2.0-84952324497 | - |
dc.identifier.wosid | 000367918400004 | - |
dc.identifier.bibliographicCitation | EARTHQUAKES AND STRUCTURES, v.9, no.6, pp.1193 - 1219 | - |
dc.relation.isPartOf | EARTHQUAKES AND STRUCTURES | - |
dc.citation.title | EARTHQUAKES AND STRUCTURES | - |
dc.citation.volume | 9 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1193 | - |
dc.citation.endPage | 1219 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.relation.journalWebOfScienceCategory | Engineering, Geological | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | BEHAVIOR | - |
dc.subject.keywordAuthor | reinforced concrete | - |
dc.subject.keywordAuthor | earthquake simulation test | - |
dc.subject.keywordAuthor | wall | - |
dc.subject.keywordAuthor | slab | - |
dc.subject.keywordAuthor | membrane action | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.