Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Constructability and heat exchange efficiency of large diameter cast-in-place energy piles with various configurations of heat exchange pipe

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Sangwoo-
dc.contributor.authorSung, Chihun-
dc.contributor.authorJung, Kyoungsik-
dc.contributor.authorSohn, Byonghu-
dc.contributor.authorChauchois, Alexis-
dc.contributor.authorChoi, Hangseok-
dc.date.accessioned2021-09-04T10:45:55Z-
dc.date.available2021-09-04T10:45:55Z-
dc.date.created2021-06-10-
dc.date.issued2015-11-05-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/91924-
dc.description.abstractA new ground heat exchanger (GHEX) assembled in a ground source heat pump (GSHP) system has been devised, which is equipped in a structural pile, and thus called an "energy pile". In this study, six large-diameter cast-in-place energy piles that encased various types of heat exchange pipes (i.e., three parallel U-types with 5 pairs, 8 pairs and 10 pairs; two coil-types with 200 mm coil pitch and 500 mm coil pitch; and S-type) were constructed in a test bed, and the constructability of each type of the energy pile was compared. Additionally, a 30 m-deep closed-loop vertical GHEX was separately constructed to compare the thermal performance and economic feasibility with the energy piles. A series of in-situ thermal response tests (TRTs) was performed to evaluate the relative heat exchange efficiency of each energy pile according to the various heat exchange pipe configurations. The relative heat exchange efficiency obtained in the cast-in-place energy piles and the down-sized 30 m-deep closed-loop vertical GHEX was normalized by the pile length (or borehole length) and the total heat exchange pipe length. The result from the in-situ tests indicates that the longer the heat exchange pipe installed, the higher heat exchange efficiency per pile length. However, in the case of tight layouts of the heat exchange pipe, thermal interference occurs between adjacent pipe loops, which decreases heat exchange efficiency. Economic feasibility of the energy piles was evaluated, considering the material and installation costs for assembling the heat exchange pipe with consideration of the heat exchange efficiency. It is concluded that the coil-type cast-in-place energy pile can achieve sufficient capacity for heat exchange, compared with the closed-loop vertical GHEX. (C) 2015 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectTHERMAL RESPONSE TEST-
dc.subjectPERFORMANCE-
dc.subjectBEHAVIOR-
dc.subjectSYSTEM-
dc.titleConstructability and heat exchange efficiency of large diameter cast-in-place energy piles with various configurations of heat exchange pipe-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Hangseok-
dc.identifier.doi10.1016/j.applthermaleng.2015.05.044-
dc.identifier.scopusid2-s2.0-84930698297-
dc.identifier.wosid000364246500111-
dc.identifier.bibliographicCitationAPPLIED THERMAL ENGINEERING, v.90, pp.1061 - 1071-
dc.relation.isPartOfAPPLIED THERMAL ENGINEERING-
dc.citation.titleAPPLIED THERMAL ENGINEERING-
dc.citation.volume90-
dc.citation.startPage1061-
dc.citation.endPage1071-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordPlusTHERMAL RESPONSE TEST-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusBEHAVIOR-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorClosed-loop vertical ground heat exchanger-
dc.subject.keywordAuthorEnergy pile-
dc.subject.keywordAuthorIn-situ thermal response test-
dc.subject.keywordAuthorConstructability of energy pile-
dc.subject.keywordAuthorRelative heat exchange efficiency-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, HANG SEOK photo

CHOI, HANG SEOK
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE