The Efficacy of Intraoperative Neuromonitoring During Robotic Thyroidectomy: A Prospective, Randomized Case-Control Evaluation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hye Yoon | - |
dc.contributor.author | Lee, Ju-Young | - |
dc.contributor.author | Dionigi, Gianlorenzo | - |
dc.contributor.author | Bae, Jeoung Won | - |
dc.contributor.author | Kim, Hoon Yub | - |
dc.date.accessioned | 2021-09-04T10:48:43Z | - |
dc.date.available | 2021-09-04T10:48:43Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2015-11-01 | - |
dc.identifier.issn | 1092-6429 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/91946 | - |
dc.description.abstract | Background: This study evaluates the efficacy of intraoperative neuromonitoring (IONM) on voice performance in robotic thyroidectomy. Materials and Methods: The study was based on a prospective randomized series. Between June 2011 to September 2012, 50 patients with thyroid cancer who underwent robotic thyroidectomy were enrolled. The IONM and non-IONM groups consisted of 25 patients each. Voice Handicap Index (VHI), voice range profile (VRP), and laryngoscopy were used to assess voice function before surgery and at 2 weeks, 3 months, and 6 months after the operation. Results: No palsy was diagnosed by laryngoscopy in either group. VHI values were similar in both groups. In the IONM group, there was significantly earlier recovery in VRP minimum intensity compared with the non-IONM group. However, there were no differences of mean change of VRP maximum frequency and intensity or minimum frequency between the two groups. Conclusions: We found that IONM facilitated more rapid recovery of voice function, especially in VRP minimum intensity, during robotic thyroid surgery. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MARY ANN LIEBERT, INC | - |
dc.subject | RECURRENT LARYNGEAL NERVE | - |
dc.subject | EXTERNAL BRANCH | - |
dc.subject | SURGERY | - |
dc.subject | ANATOMY | - |
dc.title | The Efficacy of Intraoperative Neuromonitoring During Robotic Thyroidectomy: A Prospective, Randomized Case-Control Evaluation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Bae, Jeoung Won | - |
dc.contributor.affiliatedAuthor | Kim, Hoon Yub | - |
dc.identifier.doi | 10.1089/lap.2014.0544 | - |
dc.identifier.scopusid | 2-s2.0-84947585188 | - |
dc.identifier.wosid | 000364766300008 | - |
dc.identifier.bibliographicCitation | JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, v.25, no.11, pp.908 - 914 | - |
dc.relation.isPartOf | JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | - |
dc.citation.title | JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | - |
dc.citation.volume | 25 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 908 | - |
dc.citation.endPage | 914 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | RECURRENT LARYNGEAL NERVE | - |
dc.subject.keywordPlus | EXTERNAL BRANCH | - |
dc.subject.keywordPlus | SURGERY | - |
dc.subject.keywordPlus | ANATOMY | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.