Accuracy of transient elastography in assessing liver fibrosis in chronic viral hepatitis: A multicentre, retrospective study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Seo, Yeon Seok | - |
dc.contributor.author | Kim, Moon Young | - |
dc.contributor.author | Kim, Seung Up | - |
dc.contributor.author | Hyun, Bae Si | - |
dc.contributor.author | Jang, Jae Young | - |
dc.contributor.author | Lee, Jin Woo | - |
dc.contributor.author | Lee, Jung Il | - |
dc.contributor.author | Suh, Sang Jun | - |
dc.contributor.author | Park, Soo Young | - |
dc.contributor.author | Park, Hana | - |
dc.contributor.author | Jung, Eun Uk | - |
dc.contributor.author | Kim, Byung Seok | - |
dc.contributor.author | Kim, In Hee | - |
dc.contributor.author | Lee, Tae Hee | - |
dc.contributor.author | Um, Soon Ho | - |
dc.contributor.author | Han, Kwang-Hyub | - |
dc.contributor.author | Kim, Sang Gyune | - |
dc.contributor.author | Paik, Soon Koo | - |
dc.contributor.author | Choi, Jong Young | - |
dc.contributor.author | Jeong, Soung Won | - |
dc.contributor.author | Jin, Young Joo | - |
dc.contributor.author | Lee, Kwan Sik | - |
dc.contributor.author | Yim, Hyung Joon | - |
dc.contributor.author | Tak, Won Young | - |
dc.contributor.author | Hwang, Seong Gyu | - |
dc.contributor.author | Lee, Youn Jae | - |
dc.contributor.author | Lee, Chang Hyeong | - |
dc.contributor.author | Kim, Dae-Ghon | - |
dc.contributor.author | Kang, Young Woo | - |
dc.contributor.author | Kim, Young Seok | - |
dc.date.accessioned | 2021-09-04T11:50:26Z | - |
dc.date.available | 2021-09-04T11:50:26Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-10 | - |
dc.identifier.issn | 1478-3223 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/92249 | - |
dc.description.abstract | Background/AimsTransient elastography (TE) has become an alternative to liver biopsy (LB). This study investigated the diagnostic performance of liver stiffness (LS) measurement using TE in Korean patients with chronic hepatitis B and C (CHB and CHC). MethodsFrom April 2006 to June 2014, 916 patients (567 CHB and 349 CHC) who underwent LB and TE at 15 centres were analyzed. The Batts and Ludwig scoring system was used for histologic assessment. Aspartate aminotransferase (AST)-to-platelet ratio indexes (APRI) were calculated. Area under the receiver operating characteristic curve (AUROC) was used. ResultsThe median age, LS value, and APRI score were 45years, 8.8kPa, and 0.61, respectively, in CHB patients vs. 51years, 6.8kPa and 0.55, respectively, in CHC patients. TE was significantly superior to APRI in CHB patients (AUROC 0.774 vs. 0.72 for F2, 0.849 vs. 0.812 for F3, and 0.902 vs. 0.707 for F4, respectively; all P<0.05). Furthermore, TE was significantly superior for predicting F3 stage (AUROC 0.865 vs. 0.840, P=0.009) whereas it was similar for predicting F2 and F4 stage (AUROC 0.822 vs. 0.796; 0.910 vs. 0.884; all P>0.05) in CHC patients. In CHB patients, optimal cut-off LS values were 7.8kPa for F2, 8.2kPa for F3, and 11.6kPa for F4, vs. 6.8kPa, 8.6kPa, and 14.5kPa, respectively, in CHC patients. ConclusionsTE can accurately assess the degree of liver fibrosis in Korean patients with CVH. TE was superior to APRI for predicting each fibrosis stage. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | STIFFNESS MEASUREMENT | - |
dc.subject | ALANINE AMINOTRANSFERASE | - |
dc.subject | PORTAL-HYPERTENSION | - |
dc.subject | CIRRHOSIS | - |
dc.subject | PERFORMANCE | - |
dc.subject | PREDICTION | - |
dc.subject | UPDATE | - |
dc.subject | BIOPSY | - |
dc.title | Accuracy of transient elastography in assessing liver fibrosis in chronic viral hepatitis: A multicentre, retrospective study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Seo, Yeon Seok | - |
dc.contributor.affiliatedAuthor | Um, Soon Ho | - |
dc.contributor.affiliatedAuthor | Yim, Hyung Joon | - |
dc.identifier.doi | 10.1111/liv.12808 | - |
dc.identifier.scopusid | 2-s2.0-84942373180 | - |
dc.identifier.wosid | 000362201800006 | - |
dc.identifier.bibliographicCitation | LIVER INTERNATIONAL, v.35, no.10, pp.2246 - 2255 | - |
dc.relation.isPartOf | LIVER INTERNATIONAL | - |
dc.citation.title | LIVER INTERNATIONAL | - |
dc.citation.volume | 35 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 2246 | - |
dc.citation.endPage | 2255 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
dc.subject.keywordPlus | STIFFNESS MEASUREMENT | - |
dc.subject.keywordPlus | ALANINE AMINOTRANSFERASE | - |
dc.subject.keywordPlus | PORTAL-HYPERTENSION | - |
dc.subject.keywordPlus | CIRRHOSIS | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | PREDICTION | - |
dc.subject.keywordPlus | UPDATE | - |
dc.subject.keywordPlus | BIOPSY | - |
dc.subject.keywordAuthor | chronic liver disease | - |
dc.subject.keywordAuthor | cirrhosis | - |
dc.subject.keywordAuthor | Fibroscan | - |
dc.subject.keywordAuthor | liver fibrosis | - |
dc.subject.keywordAuthor | liver stiffness | - |
dc.subject.keywordAuthor | performance | - |
dc.subject.keywordAuthor | Transient elastography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.