dc.description.abstractPURPOSE: To evaluate the accuracy of toric intraocular lens (IOL) calculation using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio according to the axis orientation of anterior corneal astigmatism. DESIGN: Retrospective cross-sectional study. METHODS: Nine hundred twenty-eight eyes of 928 reference subjects and 20 cataract patients (20 eyes) implanted with a toric IOL were enrolled. Linear regression analysis parameters (beta(0) and beta(1)) of relationship between the simulated keratometry cylinder (Cyl(SimK)) and posterior corneal cylinder power of reference subjects were used to calculate the estimated posterior corneal astigmatism (-[beta(1) x cyl(SimK) + beta(0)] @ 90). When regression analysis was not significant, estimated posterior corneal astigmatism was defined as the negative value of the mean posterior corneal cylinder power @ 90. Estimated total corneal astigmatism was defined as the vectorial sum of anterior corneal astigmatism and estimated posterior corneal astigmatism. Residual astigmatism error, predicted using SimK, was compared with that predicted using estimated total corneal astigmatism. RESULTS: Estimated posterior corneal astigmatism was determined to be -(0.15 x Cyl(SimK) + 0.22) @ 90 in eyes with with-the-rule astigmatism, -(0.05 x Cyl(SimK) + 0.27) @ 90 in oblique astigmatism, and -0.27 @ 90 in against-the-rule astigmatism. The median magnitude of the predicted residual astigmatism error calculated using estimated total corneal astigmatism (0.30 cylinder diopters) was significantly smaller than that calculated with SimK (0.50 cylinder diopters). CONCLUSIONS: Toric IOL calculations using estimated total corneal astigmatism based on the anterior-to-posterior corneal cylinder power ratio provided a more appropriate toric IOL cylinder power than calculations using SimK astigmatism. (C) 2015 by Elsevier Inc. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectASTIGMATISM-
dc.subjectCURVATURE-
dc.titleToric Intraocular Lens Calculations Using Ratio, of Anterior to Posterior Corneal Cylinder Power-
dc.typeArticle-
dc.contributor.affiliatedAuthorEom, Youngsub-
dc.contributor.affiliatedAuthorKim, Seong-Woo-
dc.contributor.affiliatedAuthorSong, Jong Suk-
dc.contributor.affiliatedAuthorKim, Hyo Myung-
dc.identifier.doi10.1016/j.ajo.2015.07.011-
dc.identifier.scopusid2-s2.0-84941414792-
dc.identifier.wosid000361503400013-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF OPHTHALMOLOGY, v.160, no.4, pp.717 - 724-
dc.relation.isPartOfAMERICAN JOURNAL OF OPHTHALMOLOGY-
dc.citation.titleAMERICAN JOURNAL OF OPHTHALMOLOGY-
dc.citation.volume160-
dc.citation.number4-
dc.citation.startPage717-
dc.citation.endPage724-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusASTIGMATISM-
dc.subject.keywordPlusCURVATURE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE