Adaptive optimization of reference intensity for optical coherence imaging using galvanometric mirror tilting method
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Ji-hyun | - |
dc.contributor.author | Han, Jae-Ho | - |
dc.contributor.author | Jeong, Jichai | - |
dc.date.accessioned | 2021-09-04T12:42:20Z | - |
dc.date.available | 2021-09-04T12:42:20Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-09-15 | - |
dc.identifier.issn | 0030-4018 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/92474 | - |
dc.description.abstract | Integration time and reference intensity are important factors for achieving high signal-to-noise ratio (SNR) and sensitivity in optical coherence tomography (OCT). In this context, we present an adaptive optimization method of reference intensity for OCT setup. The reference intensity is automatically controlled by tilting a beam position using a Galvanometric scanning mirror system. Before sample scanning, the OCT system acquires two dimensional intensity map with normalized intensity and variables in color spaces using false-color mapping. Then, the system increases or decreases reference intensity following the map data for optimization with a given algorithm. In our experiments, the proposed method successfully corrected the reference intensity with maintaining spectral shape, enabled to change integration time without manual calibration of the reference intensity, and prevented image degradation due to over-saturation and insufficient reference intensity. Also, SNR and sensitivity could be improved by increasing integration time with automatic adjustment of the reference intensity. We believe that our findings can significantly aid in the optimization of SNR and sensitivity for optical coherence tomography systems. (C) 2015 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER | - |
dc.subject | TOMOGRAPHY | - |
dc.subject | NOISE | - |
dc.subject | SENSITIVITY | - |
dc.title | Adaptive optimization of reference intensity for optical coherence imaging using galvanometric mirror tilting method | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Han, Jae-Ho | - |
dc.contributor.affiliatedAuthor | Jeong, Jichai | - |
dc.identifier.doi | 10.1016/j.optcom.2015.04.041 | - |
dc.identifier.scopusid | 2-s2.0-84928710948 | - |
dc.identifier.wosid | 000357552200010 | - |
dc.identifier.bibliographicCitation | OPTICS COMMUNICATIONS, v.351, pp.57 - 62 | - |
dc.relation.isPartOf | OPTICS COMMUNICATIONS | - |
dc.citation.title | OPTICS COMMUNICATIONS | - |
dc.citation.volume | 351 | - |
dc.citation.startPage | 57 | - |
dc.citation.endPage | 62 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.subject.keywordPlus | TOMOGRAPHY | - |
dc.subject.keywordPlus | NOISE | - |
dc.subject.keywordPlus | SENSITIVITY | - |
dc.subject.keywordAuthor | Optical imaging | - |
dc.subject.keywordAuthor | Biomedical imaging | - |
dc.subject.keywordAuthor | Tomography | - |
dc.subject.keywordAuthor | Optical interferometry | - |
dc.subject.keywordAuthor | Microscopy | - |
dc.subject.keywordAuthor | Optical signal detection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.