Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system

Full metadata record
DC Field Value Language
dc.contributor.authorShim, Ji Suk-
dc.contributor.authorLee, Jin Sook-
dc.contributor.authorLee, Jeong Yol-
dc.contributor.authorChoi, Yeon Jo-
dc.contributor.authorShin, Sang Wan-
dc.contributor.authorRyu, Jae Jun-
dc.date.accessioned2021-09-04T13:16:08Z-
dc.date.available2021-09-04T13:16:08Z-
dc.date.created2021-06-18-
dc.date.issued2015-09-
dc.identifier.issn1678-7757-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/92689-
dc.description.abstractObjective: This study investigated the marginal and internal adaptation of individual dental crowns fabricated using a CAD/CAM system (Sirona's BlueCam), also evaluating the effect of the software version used, and the specific parameter settings in the adaptation of crowns. Material and Methods: Forty digital impressions of a master model previously prepared were acquired using an intraoral scanner and divided into four groups based on the software version and on the spacer settings used. The versions 3.8 and 4.2 of the software were used, and the spacer parameter was set at either 40 mu m or 80 mu m. The marginal and internal fit of the crowns were measured using the replica technique, which uses a low viscosity silicone material that simulates the thickness of the cement layer. The data were analyzed using a Friedman two-way analysis of variance (ANOVA) and paired t-tests with significance level set at p<0.05 Results: The two-way ANOVA analysis showed the software version (p<0.05) and the spacer parameter (p<0.05) significantly affected the crown adaptation. The crowns designed with the version 4.2 of the software showed a better fit than those designed with the version 3.8, particularly in the axial wall and in the inner margin. The spacer parameter was more accurately represented in the version 4.2 of the software than in the version 3.8. In addition, the use of the version 4.2 of the software combined with the spacer parameter set at 80 mu m showed the least variation. On the other hand, the outer margin was not affected by the variables. Conclusion: Compared to the version 3.8 of the software, the version 4.2 can be recommended for the fabrication of well-fitting crown restorations, and for the appropriate regulation of the spacer parameter.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherUNIV SAO PAULO FAC ODONTOLOGIA BAURU-
dc.subjectIN-VITRO-
dc.subjectINTRAORAL SCANNERS-
dc.subjectCERAMIC CROWNS-
dc.subjectFIT-
dc.subjectACCURACY-
dc.subjectPRECISION-
dc.titleEffect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system-
dc.typeArticle-
dc.contributor.affiliatedAuthorShim, Ji Suk-
dc.contributor.affiliatedAuthorRyu, Jae Jun-
dc.identifier.doi10.1590/1678-775720150081-
dc.identifier.scopusid2-s2.0-84946039426-
dc.identifier.wosid000364646200011-
dc.identifier.bibliographicCitationJOURNAL OF APPLIED ORAL SCIENCE, v.23, no.5, pp.515 - 522-
dc.relation.isPartOfJOURNAL OF APPLIED ORAL SCIENCE-
dc.citation.titleJOURNAL OF APPLIED ORAL SCIENCE-
dc.citation.volume23-
dc.citation.number5-
dc.citation.startPage515-
dc.citation.endPage522-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
dc.subject.keywordPlusIN-VITRO-
dc.subject.keywordPlusINTRAORAL SCANNERS-
dc.subject.keywordPlusCERAMIC CROWNS-
dc.subject.keywordPlusFIT-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusPRECISION-
dc.subject.keywordAuthorSoftware-
dc.subject.keywordAuthorDesign-
dc.subject.keywordAuthorMargin-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryu, Jae Jun photo

Ryu, Jae Jun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE