Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Accurate Wavelength Calibration Method for Spectrometer Using Low Coherence Interferometry

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Ji-Hyun-
dc.contributor.authorHan, Jae-Ho-
dc.contributor.authorJeong, Jichai-
dc.date.accessioned2021-09-04T13:29:10Z-
dc.date.available2021-09-04T13:29:10Z-
dc.date.created2021-06-18-
dc.date.issued2015-08-15-
dc.identifier.issn0733-8724-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/92746-
dc.description.abstractDispersive spectrometers are subject to wavelength dispersion errors due to aberration, ruling errors, etc. Thus, their calibration forms an integral aspect of their usage. In this context, we present an interferometric wavelength calibration method for calibrating dispersive spectrometers. The calibration system is based on low coherence interferometry. By analyzing the sinusoidal interference patterns that are modulated in a spectrum, we determine the distribution of wavelengths in a spectrometer using the zero-crossing detection. The spectral sampling interval of the spectrometer is estimated by determining the sampling interval in the z-domain. Assigning only one wavelength to the corresponding camera pixel using a narrowband light source allows the determination of entire wavelengths accurately. We use the information of the wavelength distribution, spectral sampling interval, and wavelength data to achieve accurate calibration. Our experimental results show that the proposed method calibrates wavelength more accurately than conventional methods, since the interferometric calibration can reduce the wavelength fitting error arising from extrapolation. Moreover, the proposed calibration method can reduce the side-lobe amplitude maximally by 4.8 dB when applied to OCT imaging. We believe that our findings can significantly aid in the development of spectrometry.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectHIGH-SPEED-
dc.subjectTOMOGRAPHY-
dc.subjectRESOLUTION-
dc.subjectIMAGES-
dc.subjectLASERS-
dc.titleAccurate Wavelength Calibration Method for Spectrometer Using Low Coherence Interferometry-
dc.typeArticle-
dc.contributor.affiliatedAuthorHan, Jae-Ho-
dc.contributor.affiliatedAuthorJeong, Jichai-
dc.identifier.doi10.1109/JLT.2015.2393881-
dc.identifier.scopusid2-s2.0-84938717710-
dc.identifier.wosid000359566000006-
dc.identifier.bibliographicCitationJOURNAL OF LIGHTWAVE TECHNOLOGY, v.33, no.16, pp.3413 - 3418-
dc.relation.isPartOfJOURNAL OF LIGHTWAVE TECHNOLOGY-
dc.citation.titleJOURNAL OF LIGHTWAVE TECHNOLOGY-
dc.citation.volume33-
dc.citation.number16-
dc.citation.startPage3413-
dc.citation.endPage3418-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaTelecommunications-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryTelecommunications-
dc.subject.keywordPlusHIGH-SPEED-
dc.subject.keywordPlusTOMOGRAPHY-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordPlusIMAGES-
dc.subject.keywordPlusLASERS-
dc.subject.keywordAuthorBiomedical imaging-
dc.subject.keywordAuthorcalibration-
dc.subject.keywordAuthoroptical imaging-
dc.subject.keywordAuthoroptical interferometry-
dc.subject.keywordAuthorspectroscopy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Brain and Cognitive Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Jae Ho photo

Han, Jae Ho
뇌공학과
Read more

Altmetrics

Total Views & Downloads