Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with tonic intraocular lenses
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Eom, Youngsub | - |
dc.contributor.author | Song, Jong Suk | - |
dc.contributor.author | Kim, Yong Yeon | - |
dc.contributor.author | Kim, Hyo Myung | - |
dc.date.accessioned | 2021-09-04T13:46:06Z | - |
dc.date.available | 2021-09-04T13:46:06Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-08 | - |
dc.identifier.issn | 0886-3350 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/92827 | - |
dc.description.abstract | PURPOSE: To compare the accuracy of the SRK/T and Haigis formulas for predicting corneal astigmatism correction with a toric intraocular lens (IOL). SETTING: Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea. DESIGN: Retrospective cross-sectional study. METHODS: Eyes with an Acrysof toric IOL were enrolled in the study. The corneal plane effective cylinder power of toric IOLs (target induced astigmatism vector [TIA]) predicted by the SRK/T and Haigis formulas were compared with the cylindrical correction achieved postoperatively (surgically induced astigmatism vector [SIA]). The magnitude of error was defined as the difference between the magnitudes of the SIA and TIA. The median absolute magnitudes of error predicted by the SRK/T and Haigis formulas were compared. The median absolute errors predicted by the 2 formulas were also compared. RESULTS: The mean postoperative SIA was 1.80 diopters (D) +/- 0.55 (SD). The magnitude of error predicted by the SRK/T and Haigis formulas was 0.31 +/- 0.40 D and 0.23 +/- 0.40 D, respectively. The median absolute magnitude of error predicted by the Haigis formula was statistically significantly smaller than that predicted by the SRK/T formula (P<.001). The median absolute error predicted by the Haigis formula (0.35 D) was also statistically significantly smaller than that predicted by the SRK/T formula (0.43 D) (P=.003). CONCLUSION: The Haigis formula was more accurate than the SRK/T formula not only in predicting the refractive outcome but also in predicting corneal astigmatism correction by toric IOLs. (C) 2015 ASCRS and ESCRS | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE INC | - |
dc.subject | ANTERIOR-CHAMBER DEPTH | - |
dc.subject | CATARACT-SURGERY | - |
dc.subject | ROTATIONAL STABILITY | - |
dc.subject | POWER CALCULATIONS | - |
dc.subject | EYES | - |
dc.subject | CONSTANTS | - |
dc.subject | INCISIONS | - |
dc.title | Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with tonic intraocular lenses | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Eom, Youngsub | - |
dc.contributor.affiliatedAuthor | Song, Jong Suk | - |
dc.contributor.affiliatedAuthor | Kim, Yong Yeon | - |
dc.contributor.affiliatedAuthor | Kim, Hyo Myung | - |
dc.identifier.doi | 10.1016/j.jcrs.2014.12.053 | - |
dc.identifier.scopusid | 2-s2.0-84942869823 | - |
dc.identifier.wosid | 000362998800014 | - |
dc.identifier.bibliographicCitation | JOURNAL OF CATARACT AND REFRACTIVE SURGERY, v.41, no.8, pp.1650 - 1657 | - |
dc.relation.isPartOf | JOURNAL OF CATARACT AND REFRACTIVE SURGERY | - |
dc.citation.title | JOURNAL OF CATARACT AND REFRACTIVE SURGERY | - |
dc.citation.volume | 41 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 1650 | - |
dc.citation.endPage | 1657 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Ophthalmology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | ANTERIOR-CHAMBER DEPTH | - |
dc.subject.keywordPlus | CATARACT-SURGERY | - |
dc.subject.keywordPlus | ROTATIONAL STABILITY | - |
dc.subject.keywordPlus | POWER CALCULATIONS | - |
dc.subject.keywordPlus | EYES | - |
dc.subject.keywordPlus | CONSTANTS | - |
dc.subject.keywordPlus | INCISIONS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.