Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with tonic intraocular lenses

Full metadata record
DC Field Value Language
dc.contributor.authorEom, Youngsub-
dc.contributor.authorSong, Jong Suk-
dc.contributor.authorKim, Yong Yeon-
dc.contributor.authorKim, Hyo Myung-
dc.date.accessioned2021-09-04T13:46:06Z-
dc.date.available2021-09-04T13:46:06Z-
dc.date.created2021-06-18-
dc.date.issued2015-08-
dc.identifier.issn0886-3350-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/92827-
dc.description.abstractPURPOSE: To compare the accuracy of the SRK/T and Haigis formulas for predicting corneal astigmatism correction with a toric intraocular lens (IOL). SETTING: Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea. DESIGN: Retrospective cross-sectional study. METHODS: Eyes with an Acrysof toric IOL were enrolled in the study. The corneal plane effective cylinder power of toric IOLs (target induced astigmatism vector [TIA]) predicted by the SRK/T and Haigis formulas were compared with the cylindrical correction achieved postoperatively (surgically induced astigmatism vector [SIA]). The magnitude of error was defined as the difference between the magnitudes of the SIA and TIA. The median absolute magnitudes of error predicted by the SRK/T and Haigis formulas were compared. The median absolute errors predicted by the 2 formulas were also compared. RESULTS: The mean postoperative SIA was 1.80 diopters (D) +/- 0.55 (SD). The magnitude of error predicted by the SRK/T and Haigis formulas was 0.31 +/- 0.40 D and 0.23 +/- 0.40 D, respectively. The median absolute magnitude of error predicted by the Haigis formula was statistically significantly smaller than that predicted by the SRK/T formula (P<.001). The median absolute error predicted by the Haigis formula (0.35 D) was also statistically significantly smaller than that predicted by the SRK/T formula (0.43 D) (P=.003). CONCLUSION: The Haigis formula was more accurate than the SRK/T formula not only in predicting the refractive outcome but also in predicting corneal astigmatism correction by toric IOLs. (C) 2015 ASCRS and ESCRS-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectANTERIOR-CHAMBER DEPTH-
dc.subjectCATARACT-SURGERY-
dc.subjectROTATIONAL STABILITY-
dc.subjectPOWER CALCULATIONS-
dc.subjectEYES-
dc.subjectCONSTANTS-
dc.subjectINCISIONS-
dc.titleComparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with tonic intraocular lenses-
dc.typeArticle-
dc.contributor.affiliatedAuthorEom, Youngsub-
dc.contributor.affiliatedAuthorSong, Jong Suk-
dc.contributor.affiliatedAuthorKim, Yong Yeon-
dc.contributor.affiliatedAuthorKim, Hyo Myung-
dc.identifier.doi10.1016/j.jcrs.2014.12.053-
dc.identifier.scopusid2-s2.0-84942869823-
dc.identifier.wosid000362998800014-
dc.identifier.bibliographicCitationJOURNAL OF CATARACT AND REFRACTIVE SURGERY, v.41, no.8, pp.1650 - 1657-
dc.relation.isPartOfJOURNAL OF CATARACT AND REFRACTIVE SURGERY-
dc.citation.titleJOURNAL OF CATARACT AND REFRACTIVE SURGERY-
dc.citation.volume41-
dc.citation.number8-
dc.citation.startPage1650-
dc.citation.endPage1657-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusANTERIOR-CHAMBER DEPTH-
dc.subject.keywordPlusCATARACT-SURGERY-
dc.subject.keywordPlusROTATIONAL STABILITY-
dc.subject.keywordPlusPOWER CALCULATIONS-
dc.subject.keywordPlusEYES-
dc.subject.keywordPlusCONSTANTS-
dc.subject.keywordPlusINCISIONS-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Yeon photo

Kim, Yong Yeon
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE