Retrospective Estimate of the Quality of Intensity-Modulated Radiotherapy Plans for Lung Cancer

Full metadata record
DC Field Value Language
dc.contributor.authorKoo, Jihye-
dc.contributor.authorYoon, Myonggeun-
dc.contributor.authorChung, Weon Kuu-
dc.contributor.authorKim, Dong Wook-
dc.date.accessioned2021-09-04T14:25:51Z-
dc.date.available2021-09-04T14:25:51Z-
dc.date.created2021-06-16-
dc.date.issued2015-07-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/93071-
dc.description.abstractThis study estimated the planning quality of intensity-modulated radiotherapy in 42 lung cancer cases to provide preliminary data for the development of a planning quality assurance algorithm. Organs in or near the thoracic cavity (ipsilateral lung, contralateral lung, heart, liver, esophagus, spinal cord, and bronchus) were selected as organs at risk (OARs). Radiotherapy plans were compared by using the conformity index (CI), coverage index (CVI), and homogeneity index (HI) of the planning target volume (PTV), the OAR-PTV distance and the OAR-PTV overlap volume, and the V10(Gy), V20(Gy), and equivalent uniform dose (EUD) of the OARs. The CI, CVI, and HI of the PTV were 0.54 - 0.89 (0.77 +/- 0.08), 0.90 - 1.00 (0.98 +/- 0.02), and 0.11 - 0.41, (0.15 +/- 0.05), respectively. The mean EUDs (V10(Gy), V20(Gy)) of the ipsilateral lung, contralateral lung, esophagus, cord, liver, heart, and bronchus were 8.07 Gy (28.06, 13.17), 2.59 Gy (6.53, 1.18), 7.02 Gy (26.17, 12.32), 3.56 Gy (13.56, 4.48), 0.72 Gy (2.15, 0.91), 5.14 Gy (19.68, 8.62), and 10.56 Gy (36.08, 19.79), respectively. EUDs tended to decrease as the OAR-PTV distance increased and the OAR-PTV overlap volume decreased. Because the plans in this study were from a single department, relatively few people were involved in treatment planning. Differences in treatment results for a given patient would be much more pronounced if many departments were involved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectHIGH-ENERGY PHOTON-
dc.subjectRADIATION-THERAPY-
dc.subjectBREAST-CANCER-
dc.subjectRISK-
dc.subjectDOSIMETRY-
dc.subjectTRIAL-
dc.subjectWOMEN-
dc.subjectBEAMS-
dc.titleRetrospective Estimate of the Quality of Intensity-Modulated Radiotherapy Plans for Lung Cancer-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Myonggeun-
dc.identifier.doi10.3938/jkps.67.136-
dc.identifier.scopusid2-s2.0-84938354975-
dc.identifier.wosid000358616200021-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.67, no.1, pp.136 - 141-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume67-
dc.citation.number1-
dc.citation.startPage136-
dc.citation.endPage141-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002012973-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusHIGH-ENERGY PHOTON-
dc.subject.keywordPlusRADIATION-THERAPY-
dc.subject.keywordPlusBREAST-CANCER-
dc.subject.keywordPlusRISK-
dc.subject.keywordPlusDOSIMETRY-
dc.subject.keywordPlusTRIAL-
dc.subject.keywordPlusWOMEN-
dc.subject.keywordPlusBEAMS-
dc.subject.keywordAuthorPlanning quality-
dc.subject.keywordAuthorQuality assurance-
dc.subject.keywordAuthorLung cancer-
dc.subject.keywordAuthorDosimetry-
dc.subject.keywordAuthorDose-volume histogram-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE