Sampling Polyhexamethylene Guanidine Aerosols Using Eosin Y-coated Glass Beads
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Sang-Hyun | - |
dc.contributor.author | Park, Seon-Kyung | - |
dc.contributor.author | Kang, Hyun-Joong | - |
dc.contributor.author | Lee, Kyuhong | - |
dc.contributor.author | Kwon, Jung-Hwan | - |
dc.date.accessioned | 2021-09-04T14:31:54Z | - |
dc.date.available | 2021-09-04T14:31:54Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2015-07 | - |
dc.identifier.issn | 0253-2964 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/93114 | - |
dc.description.abstract | Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6x10(-6)m(3)/h for the sampler area of 22cm(2). This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at 2000rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY-V C H VERLAG GMBH | - |
dc.title | Sampling Polyhexamethylene Guanidine Aerosols Using Eosin Y-coated Glass Beads | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kwon, Jung-Hwan | - |
dc.identifier.doi | 10.1002/bkcs.10345 | - |
dc.identifier.scopusid | 2-s2.0-84936748061 | - |
dc.identifier.wosid | 000357430700016 | - |
dc.identifier.bibliographicCitation | BULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.36, no.7, pp.1819 - 1823 | - |
dc.relation.isPartOf | BULLETIN OF THE KOREAN CHEMICAL SOCIETY | - |
dc.citation.title | BULLETIN OF THE KOREAN CHEMICAL SOCIETY | - |
dc.citation.volume | 36 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 1819 | - |
dc.citation.endPage | 1823 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002010197 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.subject.keywordAuthor | Passive samplers | - |
dc.subject.keywordAuthor | Exposure assessment | - |
dc.subject.keywordAuthor | Colorimetry | - |
dc.subject.keywordAuthor | Indoor air | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.