Coordinated Voltage-Reactive Power Control Schemes Based on PMU Measurement at Automated Substations
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Yun-Hyuk | - |
dc.contributor.author | Kang, Sang-Gyun | - |
dc.contributor.author | Lee, Byongjun | - |
dc.date.accessioned | 2021-09-04T14:52:59Z | - |
dc.date.available | 2021-09-04T14:52:59Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2015-07 | - |
dc.identifier.issn | 1975-0102 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/93182 | - |
dc.description.abstract | This paper deals with methodology to control an automatic substation system. The control system can predict the power system condition by a voltage stability index (VSI). The strategies in this paper is called as Voltage-Reactive Power Control (VRPC), which regulates an abnormal voltage of a target substation by using coordination between tap changers and shunt capacitor/reactor. This method is efficient for better voltage profile. The monitoring substation includes whole of substations around the contingency event. The control quantities of the monitoring substations are decided by the calculation of the VSI, called as a Z-index. Case studies with BC Hydro-Quebec system are presented to illustrate this approach using real-time simulator. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN INST ELECTR ENG | - |
dc.title | Coordinated Voltage-Reactive Power Control Schemes Based on PMU Measurement at Automated Substations | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Byongjun | - |
dc.identifier.doi | 10.5370/JEET.2015.10.4.1400 | - |
dc.identifier.scopusid | 2-s2.0-84981169994 | - |
dc.identifier.wosid | 000357441400002 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.10, no.4, pp.1400 - 1407 | - |
dc.relation.isPartOf | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY | - |
dc.citation.title | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY | - |
dc.citation.volume | 10 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 1400 | - |
dc.citation.endPage | 1407 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001999549 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordAuthor | VRPC | - |
dc.subject.keywordAuthor | PMU | - |
dc.subject.keywordAuthor | VSI | - |
dc.subject.keywordAuthor | V-Q plane | - |
dc.subject.keywordAuthor | Coordinated control | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.