Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

Full metadata record
DC Field Value Language
dc.contributor.authorBolotnikov, A. E.-
dc.contributor.authorAckley, K.-
dc.contributor.authorCamarda, G. S.-
dc.contributor.authorCherches, C.-
dc.contributor.authorCui, Y.-
dc.contributor.authorDe Geronimo, G.-
dc.contributor.authorFried, J.-
dc.contributor.authorHodges, D.-
dc.contributor.authorHossain, A.-
dc.contributor.authorLee, W.-
dc.contributor.authorMahler, G.-
dc.contributor.authorMaritato, M.-
dc.contributor.authorPetryk, M.-
dc.contributor.authorRoy, U.-
dc.contributor.authorSalwen, C.-
dc.contributor.authorVernon, E.-
dc.contributor.authorYang, G.-
dc.contributor.authorJames, R. B.-
dc.date.accessioned2021-09-04T14:55:24Z-
dc.date.available2021-09-04T14:55:24Z-
dc.date.created2021-06-16-
dc.date.issued2015-07-
dc.identifier.issn0034-6748-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/93201-
dc.description.abstractWe developed a robust and low-cost array of virtual Frisch-grid CdZnTe detectors coupled to a front-end readout application-specific integrated circuit (ASIC) for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6 x 6 x 15 mm(3) detectors grouped into 3 x 3 sub-arrays of 2 x 2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single-or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays' performance and reduction of their cost are possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects. (C) 2015 AIP Publishing LLC.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherAMER INST PHYSICS-
dc.subjectREADOUT-
dc.titleAn array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, W.-
dc.identifier.doi10.1063/1.4927455-
dc.identifier.scopusid2-s2.0-84938268454-
dc.identifier.wosid000358934400025-
dc.identifier.bibliographicCitationREVIEW OF SCIENTIFIC INSTRUMENTS, v.86, no.7-
dc.relation.isPartOfREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.citation.titleREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.citation.volume86-
dc.citation.number7-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusREADOUT-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE