Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Adjusted Left Atrial Emptying Fraction as a Predictor of Procedural Outcome after Catheter Ablation for Atrial Fibrillation

Full metadata record
DC Field Value Language
dc.contributor.authorIm, Sung Il-
dc.contributor.authorNa, Jin Oh-
dc.contributor.authorKim, Sun Won-
dc.contributor.authorChoi, Cheol Ung-
dc.contributor.authorKim, Jin Won-
dc.contributor.authorYong, Hwan Seok-
dc.contributor.authorKim, Eung Ju-
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorPark, Chang Gyu-
dc.contributor.authorSeo, Hong Seog-
dc.contributor.authorOh, Dong Joo-
dc.contributor.authorLim, Hong Euy-
dc.date.accessioned2021-09-04T15:18:53Z-
dc.date.available2021-09-04T15:18:53Z-
dc.date.created2021-06-18-
dc.date.issued2015-06-
dc.identifier.issn1526-6702-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/93305-
dc.description.abstractStructural remodeling of the left atrium is a risk factor for recurrent arrhythmia after catheter ablation for atrial fibrillation; however, data are sparse regarding the role of functional left atrial remodeling in predicting procedural outcomes. We evaluated whether left atrial transport function could be used to predict recurrent atrial fibrillation. From July 2008 through August 2010, we enrolled 202 consecutive patients who underwent catheter ablation for atrial fibrillation (paroxysmal=120, persistent=82). Left atrial volumes (LAVs) were measured by means of multislice computed tomography at every 10% of the R-R interval, and measurements were adjusted for body surface area to yield the LAV index (LAVI) at baseline. The left atrial emptying fraction (LAEF) was calculated according to LAV differences. During the mean follow-up period of 10 +/- 4 months after a single ablation procedure, atrial fibrillation recurred in 59 patients (paroxysmal=19, persistent=40). Multivariate analysis revealed that persistent atrial fibrillation, early mitral inflow velocity, LAVI(max), LAVI(min), LAEF, LAVI(max)/LAEF, and LAVI(min)/LAEF were all independent predictors of atrial fibrillation, but the best predictor was LAVI(min)/LAEF (beta=1.329, P=0.001). The cutoff value was 1.61 (mL/m(2))/%, and the sensitivity and specificity were 74.6% and 62.2%, respectively (area under the curve=0.761). Our study shows that adjusted left atrial emptying fraction with use of multislice computed tomography might be a useful, noninvasive method to select patients for ablation.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherTEXAS HEART INST-
dc.subjectPULMONARY-VEIN ABLATION-
dc.subjectSINUS RHYTHM-
dc.subjectVOLUME-
dc.subjectRECURRENCE-
dc.subjectECHOCARDIOGRAPHY-
dc.titleAdjusted Left Atrial Emptying Fraction as a Predictor of Procedural Outcome after Catheter Ablation for Atrial Fibrillation-
dc.typeArticle-
dc.contributor.affiliatedAuthorNa, Jin Oh-
dc.contributor.affiliatedAuthorYong, Hwan Seok-
dc.contributor.affiliatedAuthorKim, Eung Ju-
dc.contributor.affiliatedAuthorRha, Seung-Woon-
dc.contributor.affiliatedAuthorOh, Dong Joo-
dc.contributor.affiliatedAuthorLim, Hong Euy-
dc.identifier.doi10.14503/THIJ-14-4524-
dc.identifier.scopusid2-s2.0-84931830403-
dc.identifier.wosid000356222700006-
dc.identifier.bibliographicCitationTEXAS HEART INSTITUTE JOURNAL, v.42, no.3, pp.216 - 225-
dc.relation.isPartOfTEXAS HEART INSTITUTE JOURNAL-
dc.citation.titleTEXAS HEART INSTITUTE JOURNAL-
dc.citation.volume42-
dc.citation.number3-
dc.citation.startPage216-
dc.citation.endPage225-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.subject.keywordPlusPULMONARY-VEIN ABLATION-
dc.subject.keywordPlusSINUS RHYTHM-
dc.subject.keywordPlusVOLUME-
dc.subject.keywordPlusRECURRENCE-
dc.subject.keywordPlusECHOCARDIOGRAPHY-
dc.subject.keywordAuthorAtrial fibrillation/physiopathology-
dc.subject.keywordAuthoratrial function, left/physiology-
dc.subject.keywordAuthorcardiac volume-
dc.subject.keywordAuthorcatheter ablation-
dc.subject.keywordAuthorheart atria/pathology/ultrasonography-
dc.subject.keywordAuthorpredictive value of tests-
dc.subject.keywordAuthorpreoperative care/methods-
dc.subject.keywordAuthorrecurrence-
dc.subject.keywordAuthorROC curve-
dc.subject.keywordAuthortomography, X-ray computed/methods-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Eung Ju photo

Kim, Eung Ju
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE