Spectroscopic properties of large-volume virtual Frisch-grid CdMnTe detectors

Full metadata record
DC Field Value Language
dc.contributor.authorKim, K. H.-
dc.contributor.authorPark, Chansun-
dc.contributor.authorKim, Pilsu-
dc.contributor.authorCho, Shinhaeng-
dc.contributor.authorLee, Jinseo-
dc.contributor.authorHong, T. K.-
dc.contributor.authorHossain, A.-
dc.contributor.authorBolotnikov, A. E.-
dc.contributor.authorJames, R. B.-
dc.date.accessioned2021-09-04T15:24:45Z-
dc.date.available2021-09-04T15:24:45Z-
dc.date.created2021-06-18-
dc.date.issued2015-06-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/93347-
dc.description.abstractCdMnTe(CMT) is a promising alternative material for use as a room-temperature radiation detector. Frisch-grid detectors have a simple configuration and outstanding spectral performance compared with other single-carrier collection techniques. The energy resolution of large-volume virtual Frisch-grid CMT detectors was tested by using several isotopes such as Co-57, (22) Na, Ba-133, and Cs-137 together or separately. Energy resolutions of 6.7% and 2.1% were obtained for 122-keV Co-57 and 662-keV Cs-137 gamma rays, respectively, without using any additional signal processing techniques. Also, a 12-mm-thick CMT detector detected the 511-keV and 1.277-MeV gamma peaks of Na-22 with values of the full width at half maximum (FWHM) of 2.7% and 1.5%, respectively. In addition, multiple low- and high-energy gamma peaks of Ba-133 were well separated. The mobilitylifetime product calculated from the shift of the 662-keV photo-peak vs. bias by using Hecht's equation was 7 x 10 (-3) cm(2)/V. These results show the possibility of using CMT detectors in response to various requirements for gamma-ray detection at room-temperature.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectCDZNTE DETECTORS-
dc.subjectPERFORMANCE-
dc.titleSpectroscopic properties of large-volume virtual Frisch-grid CdMnTe detectors-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, K. H.-
dc.identifier.doi10.3938/jkps.66.1761-
dc.identifier.scopusid2-s2.0-84934977811-
dc.identifier.wosid000356532800021-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.66, no.11, pp.1761 - 1765-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume66-
dc.citation.number11-
dc.citation.startPage1761-
dc.citation.endPage1765-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001997849-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusCDZNTE DETECTORS-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordAuthorCdMnTe-
dc.subject.keywordAuthorCdZnTe-
dc.subject.keywordAuthorFrisch-grid-
dc.subject.keywordAuthorTraveling heater method-
dc.subject.keywordAuthorMobility-lifetime product-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE