Superconducting Fault Current Limiter Placement for Power System Protection Using the Minimax Regret Criterion
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jo, Hyung-Chul | - |
dc.contributor.author | Joo, Sung-Kwan | - |
dc.date.accessioned | 2021-09-04T15:48:38Z | - |
dc.date.available | 2021-09-04T15:48:38Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2015-06 | - |
dc.identifier.issn | 1051-8223 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/93447 | - |
dc.description.abstract | In a power grid, the distributed generations (DGs) are not generally controlled by the system operator. Fault current levels in the power grid may change because of unpredictable changes in the status of noncontrollable DGs. These changes in the fault current can have an impact on the relay coordination. In this paper, the uncertainty associated with the connection status of DGs is reflected in the relay coordination. Superconducting fault current limiter (SFCL) placement can be effective for reducing the fault current while eliminating misoperation of the relays caused by DGs. However, an SFCL may also have a negative impact on the operation of the relays. An effective SFCL placement method is needed because of the high cost of the SFCL and the impact on the power system protection. In this paper, an SFCL placement method based on the minimax regret criterion is proposed for power system protection considering the uncertainty of the DGs. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.title | Superconducting Fault Current Limiter Placement for Power System Protection Using the Minimax Regret Criterion | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Joo, Sung-Kwan | - |
dc.identifier.doi | 10.1109/TASC.2015.2411052 | - |
dc.identifier.scopusid | 2-s2.0-84926429485 | - |
dc.identifier.wosid | 000349033200031 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, v.25, no.3 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY | - |
dc.citation.title | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY | - |
dc.citation.volume | 25 | - |
dc.citation.number | 3 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordAuthor | Distributed generation (DG) | - |
dc.subject.keywordAuthor | fault current | - |
dc.subject.keywordAuthor | power system uncertainty | - |
dc.subject.keywordAuthor | relay coordination | - |
dc.subject.keywordAuthor | superconducting fault current limiter (SFCL) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.