Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Changes in the Electrical Parameters of CdTe-based Crystals During Isothermal Annealing

Full metadata record
DC Field Value Language
dc.contributor.authorFochuk, P.-
dc.contributor.authorNakonechnyi, I.-
dc.contributor.authorPanchuk, O.-
dc.contributor.authorKopach, O.-
dc.contributor.authorNykonyuk, Y.-
dc.contributor.authorGrill, R.-
dc.contributor.authorBelas, E.-
dc.contributor.authorKim, K. H.-
dc.contributor.authorBolotnikov, A. E.-
dc.contributor.authorYang, G.-
dc.contributor.authorJames, R. B.-
dc.date.accessioned2021-09-04T15:55:38Z-
dc.date.available2021-09-04T15:55:38Z-
dc.date.created2021-06-16-
dc.date.issued2015-06-
dc.identifier.issn0018-9499-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/93500-
dc.description.abstractWe observed a novel unanticipated effect in CdTe, Cd1-xZnxTe and Cd1-xMnxTe crystals whilst we were measuring the dependences of several electrical properties (e.g., specific conductivity and free-carrier density) over time. During isothermal annealing under constant thermodynamic conditions (temperatures of 450-500 degrees C and under maximal cadmium-vapor pressure), we recorded a jump-like increase in the conductivity after some similar to 1 - 2 hours of heating required to stabilize the sample's electric parameters. The values of specific conductivity and free-carrier density suddenly increased by up to tenfold, and they persisted at those levels during further ageing. At the same time, the sample's conductivity became insensitive to stoichiometric changes in the crystal. We explain this effect as reflecting a sudden reformatting of the sample's native/foreign point-defect structure. This transformation is evaluated and mathematically approximated within the framework of our model of the melting of Te-containing second-phase particles; this process releases impurities from within the particles. The respective diffusion "clouds" grow, and at the moment of their mutual percolation (infiltration), a peculiar "short circuit" is observed with striking changes in the crystals' electrical parameters.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectDETECTOR-
dc.subjectCDZNTE-
dc.titleChanges in the Electrical Parameters of CdTe-based Crystals During Isothermal Annealing-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, K. H.-
dc.identifier.doi10.1109/TNS.2015.2424720-
dc.identifier.scopusid2-s2.0-85027936351-
dc.identifier.wosid000356459900006-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.62, no.3, pp.1239 - 1243-
dc.relation.isPartOfIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.titleIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.volume62-
dc.citation.number3-
dc.citation.startPage1239-
dc.citation.endPage1243-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusDETECTOR-
dc.subject.keywordPlusCDZNTE-
dc.subject.keywordAuthorAnnealing-
dc.subject.keywordAuthorCd0.9Zn0.1Te-
dc.subject.keywordAuthorcomponent overpressure-
dc.subject.keywordAuthorcrystals-
dc.subject.keywordAuthorinclusions-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE