High-speed dual-beam, crossed line-scanning fluorescence microscope with a point confocal resolution
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeong, Hyun-Woo | - |
dc.contributor.author | Kim, Hyung-Jin | - |
dc.contributor.author | Eun, Jung | - |
dc.contributor.author | Heo, Seungjin | - |
dc.contributor.author | Lim, Mikyoung | - |
dc.contributor.author | Cho, Yong-Hoon | - |
dc.contributor.author | Kim, Beop-Min | - |
dc.date.accessioned | 2021-09-04T17:05:06Z | - |
dc.date.available | 2021-09-04T17:05:06Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-04-20 | - |
dc.identifier.issn | 1559-128X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/93821 | - |
dc.description.abstract | Line-scanning microscopes are often used to overcome the limited scanning speed of conventional point-scanning confocal microscopes, at the cost, however, of spatial resolution. In this paper, we present a dual-beam fluorescence line-scanning microscope that can restore the original confocal resolution. This microscope forms two orthogonal line foci in the object plane with perpendicular scanning directions, which create two line-scan images of the same area. From these images, the real noise and confocal characteristics are analyzed. Based on this information, we developed an image restoration algorithm to produce a final image with spatial resolution comparable to that of a conventional point-scanning confocal microscope. This algorithm was derived with the total variation regularization, and the critical image restoration factor for the algorithm was determined via an iterative process. Our results indicate that the intrinsic resolution limit of line-scanning microscopes can be overcome without subsequent deterioration in spatial resolution. (C) 2015 Optical Society of America | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | OPTICAL SOC AMER | - |
dc.subject | IN-VIVO | - |
dc.subject | ILLUMINATION | - |
dc.title | High-speed dual-beam, crossed line-scanning fluorescence microscope with a point confocal resolution | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Beop-Min | - |
dc.identifier.doi | 10.1364/AO.54.003811 | - |
dc.identifier.scopusid | 2-s2.0-84942372800 | - |
dc.identifier.wosid | 000353240700042 | - |
dc.identifier.bibliographicCitation | APPLIED OPTICS, v.54, no.12, pp.3811 - 3816 | - |
dc.relation.isPartOf | APPLIED OPTICS | - |
dc.citation.title | APPLIED OPTICS | - |
dc.citation.volume | 54 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 3811 | - |
dc.citation.endPage | 3816 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.subject.keywordPlus | IN-VIVO | - |
dc.subject.keywordPlus | ILLUMINATION | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.