Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electrical delay line multiplexing for pulsed mode radiation detectors

Full metadata record
DC Field Value Language
dc.contributor.authorVinke, Ruud-
dc.contributor.authorYeom, Jung Yeol-
dc.contributor.authorLevin, Craig S.-
dc.date.accessioned2021-09-04T17:22:12Z-
dc.date.available2021-09-04T17:22:12Z-
dc.date.created2021-06-18-
dc.date.issued2015-04-07-
dc.identifier.issn0031-9155-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/93857-
dc.description.abstractMedical imaging systems are composed of a large number of position sensitive radiation detectors to provide high resolution imaging. For example, whole-body Positron Emission Tomography (PET) systems are typically composed of thousands of scintillation crystal elements, which are coupled to photosensors. Thus, PET systems greatly benefit from methods to reduce the number of data acquisition channels, in order to reduce the system development cost and complexity. In this paper we present an electrical delay line multiplexing scheme that can significantly reduce the number of readout channels, while preserving the signal integrity required for good time resolution performance. We experimented with two 4 x 4 LYSO crystal arrays, with crystal elements having 3 mm x 3 mm x 5 mm and 3 mm x 3 mm x 20 mm dimensions, coupled to 16 Hamamatsu MPPC S10931-050P SiPM elements. Results show that each crystal could be accurately identified, even in the presence of scintillation light sharing and inter-crystal Compton scatter among neighboring crystal elements. The multiplexing configuration degraded the coincidence timing resolution from similar to 243 ps FWHM to similar to 272 ps FWHM when 16 SiPM signals were combined into a single channel for the 4 x 4 LYSO crystal array with 3 mm x 3 mm x 20 mm crystal element dimensions, in coincidence with a 3 mm x 3 mm x 5 mm LYSO crystal pixel. The method is flexible to allow multiplexing configurations across different block detectors, and is scalable to an entire ring of detectors.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.subjectSILICON PHOTOMULTIPLIER-
dc.subjectAVALANCHE PHOTODIODES-
dc.subjectREADOUT ELECTRONICS-
dc.subjectTIMING RESOLUTION-
dc.subjectTIME-
dc.titleElectrical delay line multiplexing for pulsed mode radiation detectors-
dc.typeArticle-
dc.contributor.affiliatedAuthorYeom, Jung Yeol-
dc.identifier.doi10.1088/0031-9155/60/7/2785-
dc.identifier.scopusid2-s2.0-84925673059-
dc.identifier.wosid000352516000013-
dc.identifier.bibliographicCitationPHYSICS IN MEDICINE AND BIOLOGY, v.60, no.7, pp.2785 - 2802-
dc.relation.isPartOfPHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.titlePHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.volume60-
dc.citation.number7-
dc.citation.startPage2785-
dc.citation.endPage2802-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusSILICON PHOTOMULTIPLIER-
dc.subject.keywordPlusAVALANCHE PHOTODIODES-
dc.subject.keywordPlusREADOUT ELECTRONICS-
dc.subject.keywordPlusTIMING RESOLUTION-
dc.subject.keywordPlusTIME-
dc.subject.keywordAuthorradiation detectors-
dc.subject.keywordAuthormultiplexing-
dc.subject.keywordAuthortime-of-flight (TOF)-
dc.subject.keywordAuthorpositron emission tomography (PET)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE