Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Jong-Kyoung | - |
dc.contributor.author | Lee, Wan-Sun | - |
dc.contributor.author | Kim, Hae-Young | - |
dc.contributor.author | Kim, Woong-Chul | - |
dc.contributor.author | Kim, Ji-Hwan | - |
dc.date.accessioned | 2021-09-04T17:36:45Z | - |
dc.date.available | 2021-09-04T17:36:45Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-04 | - |
dc.identifier.issn | 2005-7806 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/93927 | - |
dc.description.abstract | PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (alpha=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 mu m). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN ACAD PROSTHODONTICS | - |
dc.subject | MARGINAL FIT | - |
dc.subject | INTERNAL FIT | - |
dc.subject | CROWNS | - |
dc.subject | RESTORATIONS | - |
dc.subject | TECHNOLOGY | - |
dc.subject | PROSTHESES | - |
dc.subject | ALLOYS | - |
dc.subject | FUTURE | - |
dc.title | Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hae-Young | - |
dc.contributor.affiliatedAuthor | Kim, Woong-Chul | - |
dc.contributor.affiliatedAuthor | Kim, Ji-Hwan | - |
dc.identifier.doi | 10.4047/jap.2015.7.2.122 | - |
dc.identifier.scopusid | 2-s2.0-84928947824 | - |
dc.identifier.wosid | 000353855300006 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ADVANCED PROSTHODONTICS, v.7, no.2, pp.122 - 128 | - |
dc.relation.isPartOf | JOURNAL OF ADVANCED PROSTHODONTICS | - |
dc.citation.title | JOURNAL OF ADVANCED PROSTHODONTICS | - |
dc.citation.volume | 7 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 122 | - |
dc.citation.endPage | 128 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001983838 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | MARGINAL FIT | - |
dc.subject.keywordPlus | INTERNAL FIT | - |
dc.subject.keywordPlus | CROWNS | - |
dc.subject.keywordPlus | RESTORATIONS | - |
dc.subject.keywordPlus | TECHNOLOGY | - |
dc.subject.keywordPlus | PROSTHESES | - |
dc.subject.keywordPlus | ALLOYS | - |
dc.subject.keywordPlus | FUTURE | - |
dc.subject.keywordAuthor | CAD/CAM system | - |
dc.subject.keywordAuthor | Cobalt-chromium alloy | - |
dc.subject.keywordAuthor | Computer-aided milling | - |
dc.subject.keywordAuthor | Direct metal laser sintering | - |
dc.subject.keywordAuthor | Marginal and internal fit | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.