Analysis of out-of-hospital cardiac arrest location and public access defibrillator placement in Metropolitan Phoenix, Arizona
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moon, Sungwoo | - |
dc.contributor.author | Vadeboncoeur, Tyler F. | - |
dc.contributor.author | Kortuem, Wesley | - |
dc.contributor.author | Kisakye, Marvis | - |
dc.contributor.author | Karamooz, Madalyn | - |
dc.contributor.author | White, Bernadette | - |
dc.contributor.author | Brazil, Paula | - |
dc.contributor.author | Spaite, Daniel W. | - |
dc.contributor.author | Bobrow, Bentley J. | - |
dc.date.accessioned | 2021-09-04T17:47:25Z | - |
dc.date.available | 2021-09-04T17:47:25Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2015-04 | - |
dc.identifier.issn | 1748-3107 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/94006 | - |
dc.description.abstract | Objectives: Automated external defibrillators (AEDs) improve outcomes from out-of-hospital cardiac arrest (OHCA) but are infrequently used. We sought to compare the locations of OHCAs and AEDs in metropolitan Phoenix, Arizona. Methods: Public location OHCAs and AEDs were geocoded utilizing a statewide OHCA database (1/2010-12/2012) and AED registry. OHCAs were mapped using kernel-density estimation and overlapped with AED placements. Spearman's rho was obtained to determine the correlation between OHCA incidents and AED locations. Results: A total of 654 consecutive public location OHCAs and all 1704 non-medical facility AEDs registered in the study area were included in the analysis. High OHCA incident areas lacking AEDs were identified in the kernel-density surface map. OHCA event/AED correlation analysis showed a weak correlation (Spearman's rho = 0.283; p = 0.002). Events occurred most frequently at locations categorized as "In Cars/Roads/Parking lots" (190/654, 29.1%) and there were no identified AEDs for these areas. AEDs were placed most frequently in "Publicbusiness/Office/Workplace" and cardiac arrests occurred with the second highest frequency in this location type. Conclusion: There was a weak correlation between OHCA events and deployed AEDs. It was possible to identify areas where OHCAs occurred frequently but AEDs were lacking. The ability to correlate the sites of OHCAs and AED locations is a necessary step toward improving the effectiveness of public access defibrillation. (C) 2015 Elsevier Ireland Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER IRELAND LTD | - |
dc.subject | AUTOMATED EXTERNAL DEFIBRILLATORS | - |
dc.subject | EMERGENCY CARDIOVASCULAR CARE | - |
dc.subject | HEART-ASSOCIATION GUIDELINES | - |
dc.subject | CARDIOPULMONARY-RESUSCITATION | - |
dc.subject | VENTRICULAR-FIBRILLATION | - |
dc.subject | SURVIVAL | - |
dc.subject | CPR | - |
dc.subject | IDENTIFICATION | - |
dc.subject | PROGRAMS | - |
dc.subject | OUTCOMES | - |
dc.title | Analysis of out-of-hospital cardiac arrest location and public access defibrillator placement in Metropolitan Phoenix, Arizona | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Moon, Sungwoo | - |
dc.identifier.doi | 10.1016/j.resuscitation.2014.10.029 | - |
dc.identifier.scopusid | 2-s2.0-84927614001 | - |
dc.identifier.wosid | 000354543900013 | - |
dc.identifier.bibliographicCitation | RESUSCITATION, v.89, pp.43 - 49 | - |
dc.relation.isPartOf | RESUSCITATION | - |
dc.citation.title | RESUSCITATION | - |
dc.citation.volume | 89 | - |
dc.citation.startPage | 43 | - |
dc.citation.endPage | 49 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalResearchArea | Emergency Medicine | - |
dc.relation.journalWebOfScienceCategory | Critical Care Medicine | - |
dc.relation.journalWebOfScienceCategory | Emergency Medicine | - |
dc.subject.keywordPlus | AUTOMATED EXTERNAL DEFIBRILLATORS | - |
dc.subject.keywordPlus | EMERGENCY CARDIOVASCULAR CARE | - |
dc.subject.keywordPlus | HEART-ASSOCIATION GUIDELINES | - |
dc.subject.keywordPlus | CARDIOPULMONARY-RESUSCITATION | - |
dc.subject.keywordPlus | VENTRICULAR-FIBRILLATION | - |
dc.subject.keywordPlus | SURVIVAL | - |
dc.subject.keywordPlus | CPR | - |
dc.subject.keywordPlus | IDENTIFICATION | - |
dc.subject.keywordPlus | PROGRAMS | - |
dc.subject.keywordPlus | OUTCOMES | - |
dc.subject.keywordAuthor | Automated external defibrillator | - |
dc.subject.keywordAuthor | Cardiac arrest | - |
dc.subject.keywordAuthor | Defibrillation | - |
dc.subject.keywordAuthor | Resuscitation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.