Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Relative constructability and thermal performance of cast-in-place concrete energy pile: Coil-type GHEX (ground heat exchanger)

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Sangwoo-
dc.contributor.authorLee, Dongseop-
dc.contributor.authorChoi, Hyun-Jun-
dc.contributor.authorJung, Kyoungsik-
dc.contributor.authorChoi, Hangseok-
dc.date.accessioned2021-09-04T18:28:03Z-
dc.date.available2021-09-04T18:28:03Z-
dc.date.created2021-06-15-
dc.date.issued2015-03-01-
dc.identifier.issn0360-5442-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/94173-
dc.description.abstractEnergy piles encase heat exchange pipes in a pile foundation to use geothermal energy. This paper evaluates the constructability and thermal performance of energy piles equipped in a large-diameter drilled shaft. Two energy piles were constructed by fabricating coil-type heat exchange pipes in cast-in-place concrete piles. The coil pitch was designed to be 200 mm and 500 mm, respectively. The constructability of each energy pile was evaluated in terms of time and ease for installing. In-situ TRTs were performed to compare the thermal performance of energy piles. The relative heat exchange efficiency for the coil pitch 200 mm is only 1.2 times greater than that of the coil pitch 500 mm energy pile, even though the coil pitch 200 mm energy pile encases the heat exchange pipe 2.4 times as longer as the coil pitch 500 mm. In addition, the result of TRTs was compared with two well-known analytical to estimate thermal properties of ground formation. A thermal performance test was carried out by applying artificial cooling operation to the energy piles, and indicates the heat exchange rate is not directly proportional to the pipe length because the tighter coil pitch configuration may cause thermal interference between the coil loops. (C) 2014 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectBEHAVIOR-
dc.titleRelative constructability and thermal performance of cast-in-place concrete energy pile: Coil-type GHEX (ground heat exchanger)-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Hangseok-
dc.identifier.doi10.1016/j.energy.2014.08.012-
dc.identifier.scopusid2-s2.0-84924813110-
dc.identifier.wosid000351248200009-
dc.identifier.bibliographicCitationENERGY, v.81, pp.56 - 66-
dc.relation.isPartOfENERGY-
dc.citation.titleENERGY-
dc.citation.volume81-
dc.citation.startPage56-
dc.citation.endPage66-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusBEHAVIOR-
dc.subject.keywordAuthorCast-in-place energy pile-
dc.subject.keywordAuthorCoil-type ground heat exchanger-
dc.subject.keywordAuthorIn-situ thermal response test-
dc.subject.keywordAuthorThermal performance test-
dc.subject.keywordAuthorRing-coil source model-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, HANG SEOK photo

CHOI, HANG SEOK
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE