Pulmonary nodule size evaluation with chest tomosynthesis and CT: a phantom study

Full metadata record
DC Field Value Language
dc.contributor.authorShim, S. S.-
dc.contributor.authorOh, Y-W-
dc.contributor.authorKong, K. A.-
dc.contributor.authorRyu, Y. J.-
dc.contributor.authorKim, Y.-
dc.contributor.authorJang, D. H.-
dc.date.accessioned2021-09-04T18:32:29Z-
dc.date.available2021-09-04T18:32:29Z-
dc.date.created2021-06-15-
dc.date.issued2015-03-
dc.identifier.issn0007-1285-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/94204-
dc.description.abstractObjective: We compared digital tomosynthesis (TOMO) and chest CT in terms of assessing the sizes of nodules located in zones where evaluation by simple radiography is limited. Methods: A total of 48 images comprising phantom nodules of four sizes in six different locations were used. Nodule size measurement errors for measurements using TOMO and CT images compared with the actual size from each observer were calculated. The inter- and intra-observer repeatability of the measured values and the agreement between the two techniques were assessed using the method described by Bland and Altman. Results: The mean measurement errors for all of the nodules and four observers were -0.84mm [standard deviation (SD), 0.60mm] on TOMO and -0.18mm (SD, 0.71mm) on CT images. The mean measurement errors for the different observers ranged from -1.11 to -0.55mm for TOMO and from -0.39 to 0.08mm for CT. Assessing the agreement between nodule size measurements using TOMO and CT resulted in mean measurement errors of -0.65mm, with a 95% limit of agreement of -2.53 to 1.22 mm for comparison of TOMO with CT. Conclusion: Our results suggest that nodule sizes obtained using TOMO and chest CT are comparable, even for nodules located in areas where the size measurement is limited on simple radiography. Advances in knowledge: TOMO and CT can be used interchangeably, even for nodules located in a blind area on simple radiography.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBRITISH INST RADIOLOGY-
dc.subjectRECONSTRUCTION-
dc.subjectPARAMETERS-
dc.subjectOBSERVER-
dc.subjectLESIONS-
dc.titlePulmonary nodule size evaluation with chest tomosynthesis and CT: a phantom study-
dc.typeArticle-
dc.contributor.affiliatedAuthorOh, Y-W-
dc.identifier.doi10.1259/bjr.20140040-
dc.identifier.scopusid2-s2.0-84923522530-
dc.identifier.wosid000350882800001-
dc.identifier.bibliographicCitationBRITISH JOURNAL OF RADIOLOGY, v.88, no.1047-
dc.relation.isPartOfBRITISH JOURNAL OF RADIOLOGY-
dc.citation.titleBRITISH JOURNAL OF RADIOLOGY-
dc.citation.volume88-
dc.citation.number1047-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusRECONSTRUCTION-
dc.subject.keywordPlusPARAMETERS-
dc.subject.keywordPlusOBSERVER-
dc.subject.keywordPlusLESIONS-
dc.subject.keywordAuthorpulmonary nodule-
dc.subject.keywordAuthorCT-
dc.subject.keywordAuthortomosynthesis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Yu Whan photo

Oh, Yu Whan
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE