방사선치료의 다양한 EPID 영상 질평가

Full metadata record
DC Field Value Language
dc.contributor.author손순룡-
dc.contributor.author최관우-
dc.contributor.author김정민-
dc.contributor.author정회원-
dc.contributor.author권경태-
dc.contributor.author조정희-
dc.contributor.author이제희-
dc.contributor.author정재용-
dc.contributor.author김기원-
dc.contributor.author이영아-
dc.contributor.author손진현-
dc.contributor.author민정환-
dc.date.accessioned2021-09-04T21:01:53Z-
dc.date.available2021-09-04T21:01:53Z-
dc.date.created2021-06-17-
dc.date.issued2015-
dc.identifier.issn2288-3509-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/95015-
dc.description.abstractIn megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in mega-voltage X-ray imaging (MVI).We used an edge block, which consists of tungsten with dimensions of 19 (thickness) × 10 (length) × 1 (width) cm3 and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta) and Clinac®iX (Varian) were used. As for MTF results, TrueBeamTM(Varian) flattening filter free(FFF) showed the highest values of 0.46 mm-1and1.40mm-1for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and 1 mm-1DQE of 0.0026 and 0.00014, respectively.This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).-
dc.languageEnglish-
dc.language.isoen-
dc.publisher대한방사선과학회-
dc.title방사선치료의 다양한 EPID 영상 질평가-
dc.title.alternativeEvaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy-
dc.typeArticle-
dc.contributor.affiliatedAuthor김정민-
dc.identifier.doi10.17946/JRST.2015.38.4.16-
dc.identifier.bibliographicCitation방사선기술과학, v.38, no.4, pp.451 - 461-
dc.relation.isPartOf방사선기술과학-
dc.citation.title방사선기술과학-
dc.citation.volume38-
dc.citation.number4-
dc.citation.startPage451-
dc.citation.endPage461-
dc.type.rimsART-
dc.identifier.kciidART002065919-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor변조전달함수-
dc.subject.keywordAuthor잡음전력스펙트럼-
dc.subject.keywordAuthor양자검출효율-
dc.subject.keywordAuthor전자포털영상장치-
dc.subject.keywordAuthorModulation transfer function (MTF)-
dc.subject.keywordAuthorNoise power spectrum (NPS)-
dc.subject.keywordAuthorDetective quantum efficiency (DQE)-
dc.subject.keywordAuthorElectronic portal imaging device (EPID)-