소규모 사무공간에서의 건물 외피 성능에 따른 EnergyPlus와 eQuest 시뮬레이션 결과 비교에 관한 연구

Full metadata record
DC Field Value Language
dc.contributor.author나정욱-
dc.contributor.author박두용-
dc.contributor.author김강수-
dc.date.accessioned2021-09-04T22:02:29Z-
dc.date.available2021-09-04T22:02:29Z-
dc.date.created2021-06-17-
dc.date.issued2015-
dc.identifier.issn2733-6239-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/95391-
dc.description.abstractThe purpose of this study is to compare two building energy simulation programs'(EnergyPlus and eQuest) heating/cooling load, and to find the differences by analyzing algorithm, input method and default input parameters based on the ASHRAE Standard 140-Case600. EnergyPlus calculates the inside surface temperatures by solving the heat balance, but eQuest assumes that the inside surface temperature of a thermal zone is equal to the zone air temperature. This result in zone air temperature difference(1.16 ℃ average) is due to occurred load differences. Change of U-value of vertical surface causes as 7∼8 % of the heating load difference and 25∼26 % of the cooling load difference. The result of changed SHGC is similar. But the result from infiltration shows a little different tendency(The heating load differences decrease from 7 % to -16 % and cooling load differences increase from -26 % to -19 %). All of these differences are caused by algorithm discrepancies of convection coefficients, actual air change rate and solar transmittance.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한건축학회-
dc.title소규모 사무공간에서의 건물 외피 성능에 따른 EnergyPlus와 eQuest 시뮬레이션 결과 비교에 관한 연구-
dc.title.alternativeComparison of Building Envelope Simulation Results between EnergyPlus and eQuest for a Small Sized Office Building-
dc.typeArticle-
dc.contributor.affiliatedAuthor김강수-
dc.identifier.doi10.5659/JAIK_PD.2015.31.6.175-
dc.identifier.bibliographicCitation대한건축학회논문집, v.31, no.6, pp.175 - 183-
dc.relation.isPartOf대한건축학회논문집-
dc.citation.title대한건축학회논문집-
dc.citation.volume31-
dc.citation.number6-
dc.citation.startPage175-
dc.citation.endPage183-
dc.type.rimsART-
dc.identifier.kciidART002001034-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor에너지플러스-
dc.subject.keywordAuthor이퀘스트-
dc.subject.keywordAuthor알고리즘-
dc.subject.keywordAuthor소규모 사무공간-
dc.subject.keywordAuthorCase600-
dc.subject.keywordAuthorEnergyplus-
dc.subject.keywordAuthoreQuest-
dc.subject.keywordAuthorAlgorithm-
dc.subject.keywordAuthorSmall Sized Office Building-
dc.subject.keywordAuthorCase600-
Files in This Item