Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교

Full metadata record
DC Field Value Language
dc.contributor.author배소연-
dc.contributor.author박진영-
dc.contributor.author김지환-
dc.contributor.author김혜영-
dc.contributor.author김명배-
dc.contributor.author김웅철-
dc.date.accessioned2021-09-04T23:46:45Z-
dc.date.available2021-09-04T23:46:45Z-
dc.date.created2021-06-17-
dc.date.issued2015-
dc.identifier.issn1229-3954-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/95845-
dc.description.abstractPurpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the threeunit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each(shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were converted into the point clouds-ASCⅡ files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with 2.17 of mean value compared to 4.44 in DCM group. The accuracy values between the two groups showed a statistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한치과기공학회-
dc.title치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교-
dc.title.alternativeThe comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines-
dc.typeArticle-
dc.contributor.affiliatedAuthor김웅철-
dc.identifier.doi10.14347/kadt.2014.37.1.9-
dc.identifier.bibliographicCitation대한치과기공학회지, v.37, no.1, pp.9 - 15-
dc.relation.isPartOf대한치과기공학회지-
dc.citation.title대한치과기공학회지-
dc.citation.volume37-
dc.citation.number1-
dc.citation.startPage9-
dc.citation.endPage15-
dc.type.rimsART-
dc.identifier.kciidART002014124-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorDental CAD/CAM system-
dc.subject.keywordAuthorAccuracy-
dc.subject.keywordAuthorThree-dimensional superimposition analysis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE