dc.description.abstract | Background. Microarrays enable high-throughput screening (HTS) of disease-related molecules, including important signaling proteins/peptides and small molecules that are in low abundance. In this study, we developed a multiplex blood bank screening platform, referred to as the Hi3-1 assay, for simultaneous detection of human immunodeficiency virus 1/2 (HIV 1/2) and hepatitis C virus (HCV). Methods. The Hi3-1 assay was tested using four panels (Panel 1, n = 4, 581 patient samples; Panel 2, n = 15 seroconversion samples; Panel 3, n = 4 performance samples; and Panel 4, n = 251 purchased positive control samples), and the results were collected by the Department of Laboratory Medicine, Korea University Medical College, Republic of Korea. The present study compares the sensitivity of the multiplex detection platform for both HIV and HCV using a sol-gel based microarray, which was based on a reference test (Architect HIV Ag/Ab Combo and Architect anti-HCV assays), in Korean patients. Results. The sensitivity of themultiplex detectionplatform for both HIV and HCV was 100%, and the specificity was 99.96% for HIV and 99.76% for HCV, which is equivalent to that of the reference test. Conclusion. We have successfully applied a novel screening technology to multiplex HIV and HCV diagnoses in a blood bank screening test. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | HINDAWI LTD | - |
dc.subject | SIMULTANEOUS SERODIAGNOSIS | - |
dc.subject | DIAGNOSTIC-ACCURACY | - |
dc.subject | HIV | - |
dc.subject | HCV | - |
dc.subject | PERFORMANCE | - |
dc.subject | INFECTION | - |
dc.subject | SENSITIVITY | - |
dc.subject | RISK | - |
dc.title | Evaluation of Novel Multiplex Antibody Kit for Human Immunodeficiency Virus 1/2 and Hepatitis C Virus Using Sol-Gel Based Microarray | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yun, Seung Gyu | - |
dc.contributor.affiliatedAuthor | Lim, Chae Seung | - |
dc.identifier.doi | 10.1155/2015/837296 | - |
dc.identifier.scopusid | 2-s2.0-84942742010 | - |
dc.identifier.wosid | 000362128300001 | - |
dc.identifier.bibliographicCitation | BIOMED RESEARCH INTERNATIONAL, v.2015 | - |
dc.relation.isPartOf | BIOMED RESEARCH INTERNATIONAL | - |
dc.citation.title | BIOMED RESEARCH INTERNATIONAL | - |
dc.citation.volume | 2015 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
dc.relation.journalResearchArea | Research & Experimental Medicine | - |
dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
dc.relation.journalWebOfScienceCategory | Medicine, Research & Experimental | - |
dc.subject.keywordPlus | SIMULTANEOUS SERODIAGNOSIS | - |
dc.subject.keywordPlus | DIAGNOSTIC-ACCURACY | - |
dc.subject.keywordPlus | HIV | - |
dc.subject.keywordPlus | HCV | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | INFECTION | - |
dc.subject.keywordPlus | SENSITIVITY | - |
dc.subject.keywordPlus | RISK | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.