Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Continuous immunosensing of myoglobin in human serum as potential companion diagnostics technique

Authors
Kim, Dong-HyungSeo, Sung-MinCho, Hyun-MoHong, Sun-JuneLim, Do-SunPaek, Se-Hwan
Issue Date
15-12월-2014
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Continuous immunosensor; Clinical sample pretreatment; Anti-serum aggregation; Baseline drift correction; Immunosensing performances
Citation
BIOSENSORS & BIOELECTRONICS, v.62, pp.234 - 241
Indexed
SCIE
SCOPUS
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
62
Start Page
234
End Page
241
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96485
DOI
10.1016/j.bios.2014.06.039
ISSN
0956-5663
Abstract
To attain early diagnosis of acute myocardial infarction (AMI) with enhanced accuracy, continuous immunosensing has been investigated to measure myoglobin concentration in real-time. To this end, a capture antibody showing rapid reaction kinetics was immobilized on the surface of a surface plasmon resonance sensor. Three problems associated with the continuous sensing of myoglobin in human serum needed to be overcome: non-specific binding of the analyte, aggregation of serum components, and drift of the sensor baseline. Non-specific binding was controlled by pretreating the sample with a detergent mixture consisting of sodium dodecyl sulfate and P20, and adjusting the micelle size and net charge. Aggregation was managed by inactivating certain serum constituents through chelation of heavy metals. Baseline drift perceived in the sensorgram was able to be corrected by compensating for the slope calculated by a linear regression. Under the optimal conditions, the continuous sensor reproducibly traced the varying doses of myoglobin over about 8 h with periodic one-point calibration every 3 h. The dose-response curve of the sensor was linear with acceptable variations (CVs < 4.91% in average) between the detection limit (31.0 ng/mL) and about 2000 ng/mL in the arithmetic scale (R-2 > 0.98), covering the clinical concentration range. The immunosensor performance correlated with the Pathfast reference system (R-2 > 0.98) and analytical consistency could be maintained for longer than a month if appropriately calibrated. Such immunosensing could be used as a companion diagnostic means along with real-time electrocardiographic measurement, significantly enhancing the sensitivity of AMI diagnosis and thereby enabling treatment at an early stage. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Soon Jun photo

Hong, Soon Jun
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE