Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison Between Preassembled and Modular Cups in Primary Cementless Total Hip Arthroplasty: A Two-Year Minimum Follow-up Study

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Young-Soo-
dc.contributor.authorHan, Seung-Beom-
dc.contributor.authorJung, Tae-Wan-
dc.date.accessioned2021-09-05T02:22:17Z-
dc.date.available2021-09-05T02:22:17Z-
dc.date.created2021-06-15-
dc.date.issued2014-12-
dc.identifier.issn0883-5403-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/96577-
dc.description.abstractWe prospectively analyzed 83 patients who underwent ceramic-on-ceramic THA using preassembled (n = 22) or modular acetabular components (n = 61) between June 2010 and June 2012. There were no significant differences in mean postoperative radiographic outcomes, functional outcomes, or complications between the two groups. Both groups showed satisfactory performance at the 2 year follow up. Only the gender of the patients was significantly different between the two groups. Half of the women had smaller acetabular diameters accommodating a cup size of only 48-50-mm. Although a preassembled cup with a 36-mm ceramic liner is proven to be safe in the short term, future research should focus on evaluating the long-term risks. (C) 2014 Elsevier Inc. All rghts reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherCHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS-
dc.subjectACETABULAR COMPONENT-
dc.subjectCERAMIC BEARINGS-
dc.subjectREPLACEMENT-
dc.subjectPLACEMENT-
dc.subjectFRACTURE-
dc.subjectLINER-
dc.titleComparison Between Preassembled and Modular Cups in Primary Cementless Total Hip Arthroplasty: A Two-Year Minimum Follow-up Study-
dc.typeArticle-
dc.contributor.affiliatedAuthorHan, Seung-Beom-
dc.identifier.doi10.1016/j.arth.2014.06.020-
dc.identifier.scopusid2-s2.0-84912561732-
dc.identifier.wosid000345150900030-
dc.identifier.bibliographicCitationJOURNAL OF ARTHROPLASTY, v.29, no.12, pp.2378 - 2382-
dc.relation.isPartOfJOURNAL OF ARTHROPLASTY-
dc.citation.titleJOURNAL OF ARTHROPLASTY-
dc.citation.volume29-
dc.citation.number12-
dc.citation.startPage2378-
dc.citation.endPage2382-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.subject.keywordPlusACETABULAR COMPONENT-
dc.subject.keywordPlusCERAMIC BEARINGS-
dc.subject.keywordPlusREPLACEMENT-
dc.subject.keywordPlusPLACEMENT-
dc.subject.keywordPlusFRACTURE-
dc.subject.keywordPlusLINER-
dc.subject.keywordAuthortotal hip arthroplasty-
dc.subject.keywordAuthorpreassembled ceramic liner-
dc.subject.keywordAuthorlarge diameter femoral head-
dc.subject.keywordAuthorthin acetabular cup-
dc.subject.keywordAuthorcementless-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE