Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of the Modulation Transfer Function of Megavoltage X-rays

Full metadata record
DC Field Value Language
dc.contributor.authorMin, Jung-Whan-
dc.contributor.authorKim, Ki-Won-
dc.contributor.authorKim, Jung-Min-
dc.contributor.authorChoi, In-Seok-
dc.contributor.authorJeong, Hoi-Woun-
dc.contributor.authorSon, Soon-Yong-
dc.contributor.authorBack, Geum-Mun-
dc.contributor.authorJung, Jae-Hong-
dc.contributor.authorJung, Jae-Yong-
dc.contributor.authorChoe, Bo-Young-
dc.date.accessioned2021-09-05T02:33:22Z-
dc.date.available2021-09-05T02:33:22Z-
dc.date.created2021-06-15-
dc.date.issued2014-12-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/96650-
dc.description.abstractThe modulation transfer function (MTF) must be measured against the requirements of the specific digital imaging application under consideration in order to evaluate the performance of detector equipment and to further develop the detector by performing quality-assurance (QA) procedures. The purpose of this study was to measure the MTF in digital megavoltage images (DMVs) for radiation therapy (RT) by using an edge block. We used 6 megavolts (MVs) of energy for the pre-sampling MTF, along with a photo-stimulating phosphor-based computed radiography (CR) system and a hexalon lead screen that contained a terbium-doped gadolinium oxysulfide granular phosphor (Gd2O2S:Tb). The DMV MTF was measured at both low and high resolutions according to changes in the dose in monitor units (MUs) by using four different detector combinations: CR-IP (image plate: photo-stimulable phosphor screen), CR-IP-Lead (image plate + lead screen), CR-IP-Regular (fast front screen + image plate + fast front screen) and CR-IP-Fast (fast back screen + image plate + fast front screen). At a low resolution, the MTF 50% and the MTF 10% when using the CR-IP detector increased by about 30% and 46%, in proportion to the increase in the dose from 1 to 20 MU, respectively. At a high resolution, the CR-IP and the CR-IP-Lead detectors showed increases in the MTF of about 8% or 10% when the dose increased from 1 to 20 MU. The present study, therefore, evaluates how edge methods can be helpful in taking MTF measurements during QA tests of a megavoltage imaging (MVI) system.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectHIGH QUANTUM EFFICIENCY-
dc.subjectPORTAL IMAGING DEVICE-
dc.subjectFLAT-PANEL IMAGER-
dc.subjectRADIOGRAPHY SYSTEMS-
dc.subjectDETECTOR PERFORMANCE-
dc.subjectMTF-
dc.subjectRESOLUTION-
dc.subjectNOISE-
dc.subjectMAGNIFICATION-
dc.subjectPROTOTYPE-
dc.titleEvaluation of the Modulation Transfer Function of Megavoltage X-rays-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Jung-Min-
dc.identifier.doi10.3938/jkps.65.1969-
dc.identifier.scopusid2-s2.0-84920607501-
dc.identifier.wosid000347455500039-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.65, no.11, pp.1969 - 1975-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume65-
dc.citation.number11-
dc.citation.startPage1969-
dc.citation.endPage1975-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001935346-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusHIGH QUANTUM EFFICIENCY-
dc.subject.keywordPlusPORTAL IMAGING DEVICE-
dc.subject.keywordPlusFLAT-PANEL IMAGER-
dc.subject.keywordPlusRADIOGRAPHY SYSTEMS-
dc.subject.keywordPlusDETECTOR PERFORMANCE-
dc.subject.keywordPlusMTF-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordPlusNOISE-
dc.subject.keywordPlusMAGNIFICATION-
dc.subject.keywordPlusPROTOTYPE-
dc.subject.keywordAuthorModulation transfer function (MTF)-
dc.subject.keywordAuthorDigital megavoltage images (DMVs)-
dc.subject.keywordAuthorMegavoltage X-ray imaging (MVI)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE