Channel selection for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hwang, Han-Jeong | - |
dc.contributor.author | Hahne, Janne Mathias | - |
dc.contributor.author | Mueller, Klaus-Robert | - |
dc.date.accessioned | 2021-09-05T04:36:42Z | - |
dc.date.available | 2021-09-05T04:36:42Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2014-10 | - |
dc.identifier.issn | 1741-2560 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/97240 | - |
dc.description.abstract | Objective. Recent studies have shown the possibility of simultaneous and proportional control of electrically powered upper-limb prostheses, but there has been little investigation on optimal channel selection. The objective of this study is to find a robust channel selection method and the channel subsets most suitable for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom (DoFs). Approach. Ten able-bodied subjects and one person with congenital upper-limb deficiency took part in this study, and performed wrist movements with various combinations of two DoFs (flexion/extension and radial/ulnar deviation). During the experiment, high density electromyographic (EMG) signals and the actual wrist angles were recorded with an 8 x 24 electrode array and a motion tracking system, respectively. The wrist angles were estimated from EMG features with ridge regression using the subsets of channels chosen by three different channel selection methods: (1) least absolute shrinkage and selection operator (LASSO), (2) sequential feature selection (SFS), and (3) uniform selection (UNI). Main results. SFS generally showed higher estimation accuracy than LASSO and UNI, but LASSO always outperformed SFS in terms of robustness, such as noise addition, channel shift and training data reduction. It was also confirmed that about 95% of the original performance obtained using all channels can be retained with only 12 bipolar channels individually selected by LASSO and SFS. Significance. From the analysis results, it can be concluded that LASSO is a promising channel selection method for accurate simultaneous and proportional prosthesis control. We expect that our results will provide a useful guideline to select optimal channel subsets when developing clinical myoelectric prosthesis control systems based on continuous movements with multiple DoFs. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.subject | CLASSIFICATION SCHEME | - |
dc.subject | PATTERN-RECOGNITION | - |
dc.subject | REAL-TIME | - |
dc.subject | EMG | - |
dc.subject | SURFACE | - |
dc.subject | KINEMATICS | - |
dc.subject | POSITION | - |
dc.subject | FORCE | - |
dc.title | Channel selection for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Mueller, Klaus-Robert | - |
dc.identifier.doi | 10.1088/1741-2560/11/5/056008 | - |
dc.identifier.scopusid | 2-s2.0-84907907837 | - |
dc.identifier.wosid | 000343234300009 | - |
dc.identifier.bibliographicCitation | JOURNAL OF NEURAL ENGINEERING, v.11, no.5 | - |
dc.relation.isPartOf | JOURNAL OF NEURAL ENGINEERING | - |
dc.citation.title | JOURNAL OF NEURAL ENGINEERING | - |
dc.citation.volume | 11 | - |
dc.citation.number | 5 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Neurosciences | - |
dc.subject.keywordPlus | CLASSIFICATION SCHEME | - |
dc.subject.keywordPlus | PATTERN-RECOGNITION | - |
dc.subject.keywordPlus | REAL-TIME | - |
dc.subject.keywordPlus | EMG | - |
dc.subject.keywordPlus | SURFACE | - |
dc.subject.keywordPlus | KINEMATICS | - |
dc.subject.keywordPlus | POSITION | - |
dc.subject.keywordPlus | FORCE | - |
dc.subject.keywordAuthor | channel selection | - |
dc.subject.keywordAuthor | least absolute shrinkage and selection operator (LASSO) | - |
dc.subject.keywordAuthor | sequential feature selection (SFS) | - |
dc.subject.keywordAuthor | uniform selection | - |
dc.subject.keywordAuthor | simultaneous myoelectric control | - |
dc.subject.keywordAuthor | prosthetic hand | - |
dc.subject.keywordAuthor | electromyography (EMG) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.