Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Two-dimensional paper chromatography-based fluorescent immunosensor for detecting acute myocardial infarction markers

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Jung-Hwan-
dc.contributor.authorKim, Min-Ha-
dc.contributor.authorMok, Rak-Sun-
dc.contributor.authorJeon, Jin-Woo-
dc.contributor.authorLim, Guei-Sam-
dc.contributor.authorChai, Chan-Young-
dc.contributor.authorPaek, Se-Hwan-
dc.date.accessioned2021-09-05T05:02:48Z-
dc.date.available2021-09-05T05:02:48Z-
dc.date.created2021-06-15-
dc.date.issued2014-09-15-
dc.identifier.issn1570-0232-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/97383-
dc.description.abstractA novel washing scheme following antigen antibody reactions with analyte was used during construction of a fluorescent immunosensor to resolve the background problem in the lateral flow assay with human serum. An immuno-membrane strip was devised to simultaneously measure cardiac troponin I (cTnI), creatinine kinase-MB isoform (CK-MB), and myoglobin to diagnose acute myocardial infarction. This strip was then installed within a cartridge containing a built-in washing solution tank, which was used to supply the solution across the signal generation pad of the strip after the immune reactions. Such cross-flow washing was initiated by onset-signaling from the internal control and began to run automatically upon sample addition. Under optimal conditions, the immunosensor displayed a stably suppressed background baseline, enabling us to attain a low detection limit for cTnI (0.05 ng/mL) as well as favorable reproducibility for repetitive measurements (relative standard deviation <10%). No interference was observed among the different complex formations at the respective analyte sites, and no artifacts were caused by sample matrices. We tested the performance relationship with the Pathfast reference system for positive serum samples (36 for cTnI, 58 for CK-MB, and 17 for myoglobin), and the correlation coefficients were >0.98. This result suggests that the new immunosensor system based on two-dimensional chromatography can be used for clinical testing. (C) 2014 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectCROSS-FLOW CHROMATOGRAPHY-
dc.subject3RD UNIVERSAL DEFINITION-
dc.subjectCARDIAC TROPONIN-I-
dc.subjectON-A-CHIP-
dc.subjectASSAYS-
dc.subjectIMMUNOASSAY-
dc.subjectSYSTEM-
dc.subjectBIOSENSORS-
dc.titleTwo-dimensional paper chromatography-based fluorescent immunosensor for detecting acute myocardial infarction markers-
dc.typeArticle-
dc.contributor.affiliatedAuthorPaek, Se-Hwan-
dc.identifier.doi10.1016/j.jchromb.2014.07.026-
dc.identifier.scopusid2-s2.0-84905369180-
dc.identifier.wosid000341468600021-
dc.identifier.bibliographicCitationJOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, v.967, pp.139 - 146-
dc.relation.isPartOfJOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES-
dc.citation.titleJOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES-
dc.citation.volume967-
dc.citation.startPage139-
dc.citation.endPage146-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusCROSS-FLOW CHROMATOGRAPHY-
dc.subject.keywordPlus3RD UNIVERSAL DEFINITION-
dc.subject.keywordPlusCARDIAC TROPONIN-I-
dc.subject.keywordPlusON-A-CHIP-
dc.subject.keywordPlusASSAYS-
dc.subject.keywordPlusIMMUNOASSAY-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusBIOSENSORS-
dc.subject.keywordAuthorCross-flow washing-
dc.subject.keywordAuthorLateral flow assay-
dc.subject.keywordAuthorSignal-to-noise ratio-
dc.subject.keywordAuthorAcute myocardial infarction triple biomarkers-
dc.subject.keywordAuthorReal human serum samples-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE