Two-dimensional paper chromatography-based fluorescent immunosensor for detecting acute myocardial infarction markers
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Jung-Hwan | - |
dc.contributor.author | Kim, Min-Ha | - |
dc.contributor.author | Mok, Rak-Sun | - |
dc.contributor.author | Jeon, Jin-Woo | - |
dc.contributor.author | Lim, Guei-Sam | - |
dc.contributor.author | Chai, Chan-Young | - |
dc.contributor.author | Paek, Se-Hwan | - |
dc.date.accessioned | 2021-09-05T05:02:48Z | - |
dc.date.available | 2021-09-05T05:02:48Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2014-09-15 | - |
dc.identifier.issn | 1570-0232 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/97383 | - |
dc.description.abstract | A novel washing scheme following antigen antibody reactions with analyte was used during construction of a fluorescent immunosensor to resolve the background problem in the lateral flow assay with human serum. An immuno-membrane strip was devised to simultaneously measure cardiac troponin I (cTnI), creatinine kinase-MB isoform (CK-MB), and myoglobin to diagnose acute myocardial infarction. This strip was then installed within a cartridge containing a built-in washing solution tank, which was used to supply the solution across the signal generation pad of the strip after the immune reactions. Such cross-flow washing was initiated by onset-signaling from the internal control and began to run automatically upon sample addition. Under optimal conditions, the immunosensor displayed a stably suppressed background baseline, enabling us to attain a low detection limit for cTnI (0.05 ng/mL) as well as favorable reproducibility for repetitive measurements (relative standard deviation <10%). No interference was observed among the different complex formations at the respective analyte sites, and no artifacts were caused by sample matrices. We tested the performance relationship with the Pathfast reference system for positive serum samples (36 for cTnI, 58 for CK-MB, and 17 for myoglobin), and the correlation coefficients were >0.98. This result suggests that the new immunosensor system based on two-dimensional chromatography can be used for clinical testing. (C) 2014 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | CROSS-FLOW CHROMATOGRAPHY | - |
dc.subject | 3RD UNIVERSAL DEFINITION | - |
dc.subject | CARDIAC TROPONIN-I | - |
dc.subject | ON-A-CHIP | - |
dc.subject | ASSAYS | - |
dc.subject | IMMUNOASSAY | - |
dc.subject | SYSTEM | - |
dc.subject | BIOSENSORS | - |
dc.title | Two-dimensional paper chromatography-based fluorescent immunosensor for detecting acute myocardial infarction markers | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Paek, Se-Hwan | - |
dc.identifier.doi | 10.1016/j.jchromb.2014.07.026 | - |
dc.identifier.scopusid | 2-s2.0-84905369180 | - |
dc.identifier.wosid | 000341468600021 | - |
dc.identifier.bibliographicCitation | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, v.967, pp.139 - 146 | - |
dc.relation.isPartOf | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | - |
dc.citation.title | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | - |
dc.citation.volume | 967 | - |
dc.citation.startPage | 139 | - |
dc.citation.endPage | 146 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | CROSS-FLOW CHROMATOGRAPHY | - |
dc.subject.keywordPlus | 3RD UNIVERSAL DEFINITION | - |
dc.subject.keywordPlus | CARDIAC TROPONIN-I | - |
dc.subject.keywordPlus | ON-A-CHIP | - |
dc.subject.keywordPlus | ASSAYS | - |
dc.subject.keywordPlus | IMMUNOASSAY | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordPlus | BIOSENSORS | - |
dc.subject.keywordAuthor | Cross-flow washing | - |
dc.subject.keywordAuthor | Lateral flow assay | - |
dc.subject.keywordAuthor | Signal-to-noise ratio | - |
dc.subject.keywordAuthor | Acute myocardial infarction triple biomarkers | - |
dc.subject.keywordAuthor | Real human serum samples | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.