Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Identification of radionuclides for the spectroscopic radiation portal monitor for pedestrian screening under a low signal-to-noise ratio condition

Full metadata record
DC Field Value Language
dc.contributor.authorMin, Eungi-
dc.contributor.authorKo, Mincheol-
dc.contributor.authorLee, Hakjae-
dc.contributor.authorKim, Yongkwon-
dc.contributor.authorJoung, Jinhun-
dc.contributor.authorJoo, Sung-Kwan-
dc.contributor.authorLee, Kisung-
dc.date.accessioned2021-09-05T05:11:23Z-
dc.date.available2021-09-05T05:11:23Z-
dc.date.created2021-06-15-
dc.date.issued2014-09-11-
dc.identifier.issn0168-9002-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/97405-
dc.description.abstractThe spectroscopic radiation portal monitor (SPM) is widely used for homeland security. Many research groups are studying the radionuclide identification method which is one of the most important factors in the performance of the SPM using the large size of a thallium activated sodium iodide (NaI(Tl)) detector. In this study, we developed the radionuclide identification method for the SPM for pedestrian screening using a single NaI(Tl) detector that is small in size (2 in.), which is much smaller than those in the existing studies under the low signal-to-noise-ratio (SNR) condition. From the anomalous radionuclide spectrum, the noise component was effectively reduced by the wavelet decomposition and the proposed background subtraction method, and the signal component was enhanced by the principal component analysis. Finally, peak locations which have been determined by the peak search algorithm with a valley check method were compared with a pre-calibrated and constructed radionuclide database. To verify the radiation identification performance of the proposed method, experiments with various kinds of sources (Cs-137, Ba-133, Na-22, and Co-57) and different SNR values (from distances of 10-150 cm and for scan times of 1-5 s) were performed. Although the high-SNR condition was explored as well, most experiments were conducted under the low-SNR condition to verify the robustness and reproducibility of the proposed algorithm. The results showed that over 98.3% of the single radionuclide detection rate was achieved regardless of which radionuclides were used, up to 50 cm under the worst SNR condition (1 s of scan Lime) and up to 90 cm under the best SNR condition (5 s of scan Lime). Furthermore we achieved accurate identification of multiple radionuclides at 40 cm with only 1 s of scan time The results show that the proposed algorithm is competitive with the commercial method and our radionuclide identification method can be successfully applied to the SPM for pedestrian monitoring, with a small detector size and a short scan time. (C) 2014 Elsevier B.V. All rights reserved,-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER-
dc.titleIdentification of radionuclides for the spectroscopic radiation portal monitor for pedestrian screening under a low signal-to-noise ratio condition-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Hakjae-
dc.contributor.affiliatedAuthorJoo, Sung-Kwan-
dc.contributor.affiliatedAuthorLee, Kisung-
dc.identifier.doi10.1016/j.nima.2014.05.021-
dc.identifier.scopusid2-s2.0-84901920901-
dc.identifier.wosid000338348900009-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.758, pp.62 - 68-
dc.relation.isPartOfNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume758-
dc.citation.startPage62-
dc.citation.endPage68-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.subject.keywordAuthorRadionuclide identification-
dc.subject.keywordAuthorSpectroscopic radiation portal monitor-
dc.subject.keywordAuthorPedestrian screening-
dc.subject.keywordAuthorSignal-to-noise ratio-
dc.subject.keywordAuthorDetection rate-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ki sung photo

Lee, Ki sung
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE