Effect of fiber length and placement method on flexural behavior, tension-softening curve, and fiber distribution characteristics of UHPFRC
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo, Doo-Yeol | - |
dc.contributor.author | Kang, Su-Tea | - |
dc.contributor.author | Yoon, Young-Soo | - |
dc.date.accessioned | 2021-09-05T06:08:55Z | - |
dc.date.available | 2021-09-05T06:08:55Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2014-08-14 | - |
dc.identifier.issn | 0950-0618 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/97684 | - |
dc.description.abstract | This study investigates the effect of fiber length and placement method on the flexural behavior, tension-softening curve, and fiber distribution characteristics of ultra-high-performance fiber-reinforced concrete (UHPFRC). Four different fiber lengths (L-f = 13, 16.3, 19.5, and 30 mm) were considered for two different placement methods. The ultimate flexural strength increased with increasing fiber length up to 19.5 mm, despite no noticeable difference in the first crack strength. Conversely, fiber length of 30 mm showed deterioration of flexural performance due to the decrease of fiber number existed across the crack surface. Both of first crack and ultimate flexural strengths were affected by the placement method; the specimen with concrete placed in the center (at maximum moment region) exhibited higher strength than that with concrete placed in the corner. The reasons were confirmed by image analysis that poorer fiber dispersion and fewer fibers across the crack surface were obtained for the specimen with concrete placed in the center than its counterpart. Finally, a tri-linear softening curve for UHPFRC was suggested based on inverse analysis and verified through comparison between the finite element analyses and the test data. (C) 2014 Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCI LTD | - |
dc.subject | SHRINKAGE | - |
dc.title | Effect of fiber length and placement method on flexural behavior, tension-softening curve, and fiber distribution characteristics of UHPFRC | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Young-Soo | - |
dc.identifier.doi | 10.1016/j.conbuildmat.2014.04.007 | - |
dc.identifier.wosid | 000338400600009 | - |
dc.identifier.bibliographicCitation | CONSTRUCTION AND BUILDING MATERIALS, v.64, pp.67 - 81 | - |
dc.relation.isPartOf | CONSTRUCTION AND BUILDING MATERIALS | - |
dc.citation.title | CONSTRUCTION AND BUILDING MATERIALS | - |
dc.citation.volume | 64 | - |
dc.citation.startPage | 67 | - |
dc.citation.endPage | 81 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.subject.keywordPlus | SHRINKAGE | - |
dc.subject.keywordAuthor | Mechanical properties | - |
dc.subject.keywordAuthor | Tension-softening curve | - |
dc.subject.keywordAuthor | Finite element analysis | - |
dc.subject.keywordAuthor | Fiber reinforcement | - |
dc.subject.keywordAuthor | Image analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.