Detection of Stator-Slot Magnetic Wedge Failures for Induction Motors Without Disassembly
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Kun Wang | - |
dc.contributor.author | Hong, Jongman | - |
dc.contributor.author | Hyun, Doosoo | - |
dc.contributor.author | Lee, Sang Bin | - |
dc.contributor.author | Wiedenbrug, Ernesto J. | - |
dc.contributor.author | Teska, Mike | - |
dc.contributor.author | Lim, Chaewoong | - |
dc.date.accessioned | 2021-09-05T07:15:09Z | - |
dc.date.available | 2021-09-05T07:15:09Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2014-07 | - |
dc.identifier.issn | 0093-9994 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/98037 | - |
dc.description.abstract | The recent trend in large ac machines is to employ magnetic stator-slot wedges for improving the motor efficiency, power factor, and power density. The mechanical strength of magnetic wedges is weak compared to the epoxy glass wedges, and many cases of loose and missing wedges have recently been increasingly reported. Magnetic wedge failure deteriorates the performance and reliability of the motor, but there is no method available for testing the wedge quality other than visual inspection after rotor removal. Monitoring of the overall wedge condition without motor disassembly can help reduce the cost of maintenance and risk of degradation in performance. In this paper, a new offline standstill test method for detecting magnetic wedge problems for ac machines without motor disassembly is proposed. An experimental study on 380-V 5.5-kW and 6.6-kV 3.4-MW motors with magnetic wedges is performed to verify the effectiveness of the new test method. It is shown that the new method can provide reliable monitoring of magnetic wedge problems over time, independent of other faults or motor design. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | MACHINES | - |
dc.title | Detection of Stator-Slot Magnetic Wedge Failures for Induction Motors Without Disassembly | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Sang Bin | - |
dc.identifier.doi | 10.1109/TIA.2013.2290869 | - |
dc.identifier.scopusid | 2-s2.0-84904655044 | - |
dc.identifier.wosid | 000340464900014 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, v.50, no.4, pp.2410 - 2419 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS | - |
dc.citation.title | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS | - |
dc.citation.volume | 50 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 2410 | - |
dc.citation.endPage | 2419 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordPlus | MACHINES | - |
dc.subject.keywordAuthor | AC machines | - |
dc.subject.keywordAuthor | fault diagnosis | - |
dc.subject.keywordAuthor | inverters | - |
dc.subject.keywordAuthor | magnetic wedges | - |
dc.subject.keywordAuthor | nondestructive testing | - |
dc.subject.keywordAuthor | stators | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.