Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Use of high-granularity position sensing to correct response non-uniformities of CdZnTe detectors

Full metadata record
DC Field Value Language
dc.contributor.authorBolotnikov, A. E.-
dc.contributor.authorCamarda, G. S.-
dc.contributor.authorCui, Y.-
dc.contributor.authorDe Geronimo, G.-
dc.contributor.authorFried, J.-
dc.contributor.authorHossain, A.-
dc.contributor.authorLee, K.-
dc.contributor.authorMahler, G.-
dc.contributor.authorMaritato, M.-
dc.contributor.authorMarshall, M.-
dc.contributor.authorPetryk, M.-
dc.contributor.authorRoy, U.-
dc.contributor.authorVernon, E.-
dc.contributor.authorYang, G.-
dc.contributor.authorJames, R. B.-
dc.date.accessioned2021-09-05T07:36:01Z-
dc.date.available2021-09-05T07:36:01Z-
dc.date.created2021-06-15-
dc.date.issued2014-06-30-
dc.identifier.issn0003-6951-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/98186-
dc.description.abstractCdZnTe (CZT) is a promising medium for room-temperature gamma-ray detectors. However, the low production yield of acceptable quality crystals hampers the use of CZT detectors for gamma-ray spectroscopy. Significant efforts have been directed towards improving quality of CZT crystals to make them generally available for radiation detectors. Another way to address this problem is to implement detector designs that would allow for more accurate and predictable correction of the charge loss associated with crystal defects. In this work, we demonstrate that high-granularity position-sensitive detectors can significantly improve the performance of CZT detectors fabricated from CZT crystals with wider acceptance boundaries, leading to an increase of their availability and expected decrease in cost. (C) 2014 AIP Publishing LLC.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherAMER INST PHYSICS-
dc.subjectCZT DETECTORS-
dc.subjectSENSITIVE DETECTORS-
dc.subjectREADOUT-
dc.subjectPERFORMANCE-
dc.titleUse of high-granularity position sensing to correct response non-uniformities of CdZnTe detectors-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, K.-
dc.identifier.doi10.1063/1.4883402-
dc.identifier.scopusid2-s2.0-84905650359-
dc.identifier.wosid000339114100062-
dc.identifier.bibliographicCitationAPPLIED PHYSICS LETTERS, v.104, no.26-
dc.relation.isPartOfAPPLIED PHYSICS LETTERS-
dc.citation.titleAPPLIED PHYSICS LETTERS-
dc.citation.volume104-
dc.citation.number26-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusCZT DETECTORS-
dc.subject.keywordPlusSENSITIVE DETECTORS-
dc.subject.keywordPlusREADOUT-
dc.subject.keywordPlusPERFORMANCE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ki sung photo

Lee, Ki sung
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE