Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fouling distribution in forward osmosis membrane process

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Junseok-
dc.contributor.authorKim, Bongchul-
dc.contributor.authorHong, Seungkwan-
dc.date.accessioned2021-09-05T08:07:38Z-
dc.date.available2021-09-05T08:07:38Z-
dc.date.created2021-06-15-
dc.date.issued2014-06-01-
dc.identifier.issn1001-0742-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/98266-
dc.description.abstractFouling behavior along the length of membrane module was systematically investigated by performing simple modeling and lab-scale experiments of forward osmosis (FO) membrane process. The flux distribution model developed in this study showed a good agreement with experimental results, validating the robustness of the model. This model demonstrated, as expected, that the permeate flux decreased along the membrane channel due to decreasing osmotic pressure differential across the FO membrane. A series of fouling experiments were conducted under the draw and feed solutions at various recoveries simulated by the model. The simulated fouling experiments revealed that higher organic (alginate) fouling and thus more flux decline were observed at the last section of a membrane channel, as foulants in feed solution became more concentrated. Furthermore, the water flux in FO process declined more severely as the recovery increased due to more foulants transported to membrane surface with elevated solute concentrations at higher recovery, which created favorable solution environments for organic adsorption. The fouling reversibility also decreased at the last section of the membrane channel, suggesting that fouling distribution on FO membrane along the module should be carefully examined to improve overall cleaning efficiency. Lastly, it was found that such fouling distribution observed with co-current flow operation became less pronounced in countercurrent flow operation of FO membrane process.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSCIENCE PRESS-
dc.subjectSEAWATER DESALINATION-
dc.subjectREVERSE-OSMOSIS-
dc.subjectWASTE-WATER-
dc.subjectPRETREATMENT-
dc.subjectBEHAVIOR-
dc.subjectFLUX-
dc.subjectRO-
dc.titleFouling distribution in forward osmosis membrane process-
dc.typeArticle-
dc.contributor.affiliatedAuthorHong, Seungkwan-
dc.identifier.doi10.1016/S1001-0742(13)60610-5-
dc.identifier.scopusid2-s2.0-84898409872-
dc.identifier.wosid000337205500020-
dc.identifier.bibliographicCitationJOURNAL OF ENVIRONMENTAL SCIENCES, v.26, no.6, pp.1348 - 1354-
dc.relation.isPartOfJOURNAL OF ENVIRONMENTAL SCIENCES-
dc.citation.titleJOURNAL OF ENVIRONMENTAL SCIENCES-
dc.citation.volume26-
dc.citation.number6-
dc.citation.startPage1348-
dc.citation.endPage1354-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.subject.keywordPlusSEAWATER DESALINATION-
dc.subject.keywordPlusREVERSE-OSMOSIS-
dc.subject.keywordPlusWASTE-WATER-
dc.subject.keywordPlusPRETREATMENT-
dc.subject.keywordPlusBEHAVIOR-
dc.subject.keywordPlusFLUX-
dc.subject.keywordPlusRO-
dc.subject.keywordAuthorforward osmosis-
dc.subject.keywordAuthormembrane module length-
dc.subject.keywordAuthororganic fouling-
dc.subject.keywordAuthorfouling reversibility-
dc.subject.keywordAuthorcounter-current flow FO operation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Seung kwan photo

Hong, Seung kwan
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE