Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fabrication and characterization of piezoelectric driven microdiaphragm resonating sensor for a biosensing application

Full metadata record
DC Field Value Language
dc.contributor.authorChae, Myung-Sic-
dc.contributor.authorLee, Sang-Myung-
dc.contributor.authorYoo, Yong Kyoung-
dc.contributor.authorLee, Soo Hyun-
dc.contributor.authorKim, Jinsik-
dc.contributor.authorKim, Tae Song-
dc.contributor.authorAhn, Dong June-
dc.contributor.authorLee, Jeong Hoon-
dc.contributor.authorHwang, Kyo Seon-
dc.date.accessioned2021-09-05T08:11:25Z-
dc.date.available2021-09-05T08:11:25Z-
dc.date.created2021-06-15-
dc.date.issued2014-06-
dc.identifier.issn1385-3449-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/98290-
dc.description.abstractThe detection capability of microresonating sensors is decided by the resonant properties (mass sensitivity and quality factor) because the microresonating sensors have detection principle that the target material of small amount quantitatively detect by measuring the resonant properties change of microresonators. Mass sensitivity is important factor to evaluate minimum detectable mass of microresonating sensors. For the biomolecule detection in liquid, microresonaotrs have to keep the quality factor that can discriminate small frequency change when the liquid sample injected on the microresonating sensors. In order to study mass sensitivity and quality factor of the fabricated microdiaphragm sensors, Pt thin film with different thicknesses are deposited on the our Pb(Zr0.52Ti0.48)O-3 layer-embedded microdiaphragm sensors. Increasing the mass sensitivity ranging from 1.68 to 36.61 Hz/ng which is found with the decreasing the width of squared microdiaphragms ranging 900 to 300 mu m. The mass sensitivity of our microdiaphragm sensor stands comparison with microcantilever sensor of length scale of 200 similar to 300 mu m. Moreover, we find that the quality factor is kept on more than 23 that was ten times better than microcantilever resonating sensor with length scale of 200 mu m.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER-
dc.subjectBIOMARKER DETECTION-
dc.subjectPZT CANTILEVER-
dc.subjectSENSITIVITY-
dc.subjectARRAY-
dc.subjectPSA-
dc.titleFabrication and characterization of piezoelectric driven microdiaphragm resonating sensor for a biosensing application-
dc.typeArticle-
dc.contributor.affiliatedAuthorAhn, Dong June-
dc.identifier.doi10.1007/s10832-014-9928-y-
dc.identifier.scopusid2-s2.0-84905235777-
dc.identifier.wosid000339721900018-
dc.identifier.bibliographicCitationJOURNAL OF ELECTROCERAMICS, v.32, no.4, pp.383 - 389-
dc.relation.isPartOfJOURNAL OF ELECTROCERAMICS-
dc.citation.titleJOURNAL OF ELECTROCERAMICS-
dc.citation.volume32-
dc.citation.number4-
dc.citation.startPage383-
dc.citation.endPage389-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryMaterials Science, Ceramics-
dc.subject.keywordPlusBIOMARKER DETECTION-
dc.subject.keywordPlusPZT CANTILEVER-
dc.subject.keywordPlusSENSITIVITY-
dc.subject.keywordPlusARRAY-
dc.subject.keywordPlusPSA-
dc.subject.keywordAuthorDiaphragm sensor-
dc.subject.keywordAuthormembrane resonator-
dc.subject.keywordAuthorquality factor-
dc.subject.keywordAuthorresonant frequency-
dc.subject.keywordAuthormass sensitivity-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Dong June photo

Ahn, Dong June
공과대학 (화공생명공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE