Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Improved remote gaze estimation using corneal reflection-adaptive geometric transforms

Full metadata record
DC Field Value Language
dc.contributor.authorMa, Chunfei-
dc.contributor.authorBaek, Seung-Jin-
dc.contributor.authorChoi, Kang-A-
dc.contributor.authorKo, Sung-Jea-
dc.date.accessioned2021-09-05T09:16:46Z-
dc.date.available2021-09-05T09:16:46Z-
dc.date.created2021-06-15-
dc.date.issued2014-05-
dc.identifier.issn0091-3286-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/98677-
dc.description.abstractRecently, the remote gaze estimation (RGE) technique has been widely applied to consumer devices as a more natural interface. In general, the conventional RGE method estimates a user's point of gaze using a geometric transform, which represents the relationship between several infrared (IR) light sources and their corresponding corneal reflections (CRs) in the eye image. Among various methods, the homography normalization (HN) method achieves state-of-the-art performance. However, the geometric transform of the HN method requiring four CRs is infeasible for the case when fewer than four CRs are available. To solve this problem, this paper proposes a new RGE method based on three alternative geometric transforms, which are adaptive to the number of CRs. Unlike the HN method, the proposed method not only can operate with two or three CRs, but can also provide superior accuracy. To further enhance the performance, an effective error correction method is also proposed. By combining the introduced transforms with the error-correction method, the proposed method not only provides high accuracy and robustness for gaze estimation, but also allows for a more flexible system setup with a different number of IR light sources. Experimental results demonstrate the effectiveness of the proposed method. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE)-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS-
dc.subjectEYE-GAZE-
dc.subjectCROSS-RATIO-
dc.subjectTRACKING-
dc.titleImproved remote gaze estimation using corneal reflection-adaptive geometric transforms-
dc.typeArticle-
dc.contributor.affiliatedAuthorKo, Sung-Jea-
dc.identifier.doi10.1117/1.OE.53.5.053112-
dc.identifier.scopusid2-s2.0-84901020253-
dc.identifier.wosid000340680800030-
dc.identifier.bibliographicCitationOPTICAL ENGINEERING, v.53, no.5-
dc.relation.isPartOfOPTICAL ENGINEERING-
dc.citation.titleOPTICAL ENGINEERING-
dc.citation.volume53-
dc.citation.number5-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.subject.keywordPlusEYE-GAZE-
dc.subject.keywordPlusCROSS-RATIO-
dc.subject.keywordPlusTRACKING-
dc.subject.keywordAuthorremote gaze estimation-
dc.subject.keywordAuthorgeometric transforms-
dc.subject.keywordAuthorerror correction-
dc.subject.keywordAuthorflexibility-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE