The level of submicron fungal fragments in homes with asthmatic children
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Seo, SungChul | - |
dc.contributor.author | Choung, Ji Tae | - |
dc.contributor.author | Chen, Bean T. | - |
dc.contributor.author | Lindsley, William G. | - |
dc.contributor.author | Kim, Ki Youn | - |
dc.date.accessioned | 2021-09-05T09:17:34Z | - |
dc.date.available | 2021-09-05T09:17:34Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2014-05 | - |
dc.identifier.issn | 0013-9351 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/98683 | - |
dc.description.abstract | Objectives: Much scientific evidence indicates a positive association between moldy environments and respiratory illnesses and/or symptoms (e.g., asthma). Recently, submicron fungal fragments (< 1.0 mu m) have been suggested as a potential contributor to adverse health effects due to their biological composition (e.g., antigens, mycotoxins, and (1,3)-beta-D-glucan) as well as their small size. However, the contribution of exposure to fine fungal particles on adverse health outcomes has been poorly characterized, particularly in homes with asthmatic children. We characterized the airborne level of smaller-sized fungal particles between homes with and without asthmatic children. Methods: We visited 29 homes with (n=15) and without (n=14) an asthmatic child and sampled submicron fungal fragments in a living room and child's bedroom, along with outdoor sampling, using the NIOSH two-stage sampler. (1,3)-beta-D-glucan of fungal fragments analyzed by Limulus Amebocyte lysate assay (LAL) was used for quantifying their exposure. Results: Overall, the geometric mean (GM) concentration of (1,3)-beta-D-glucan in submicron fungal fragments in indoor air was two-fold higher in homes with asthmatic children (50.9 pg/m(3)) compared to homes with non-asthmatic children (26.7 pg/m(3)) (P < 0.001). The GM concentration of these particles in child's bedroom in homes with an asthmatic child (66.1 pg/m(3)) was about three times higher than that in homes with non-asthmatic children (23.0 pg/m(3)) (P < 0.001). The relative humidity had a negative correlation with the concentration of (1,3)-beta-D-glucan in submicron fungal fragments (Pearson coefficient=-0.257, P=0.046). Conclusions: Our findings indicate that homes with asthmatic children have a higher concentration of submicron fungal fragments compared to homes with non-asthmatic children. A greater exposure to smaller-sized fungal particles may occur in homes with an asthmatic child as relative humidity decreases. The very careful control of relative humidity in indoor air is necessary for reducing exposure to fine fungal particles and inhibiting the growth of microorganisms in homes with allergic diseases. (C) 2014 Elsevier Inc. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ACADEMIC PRESS INC ELSEVIER SCIENCE | - |
dc.subject | RELATIVE MOLDINESS INDEX | - |
dc.subject | AIR-POLLUTION | - |
dc.subject | ULTRAFINE PARTICLES | - |
dc.subject | RESPIRATORY HEALTH | - |
dc.subject | URBAN AIR | - |
dc.subject | MOLD | - |
dc.subject | EXPOSURE | - |
dc.subject | AEROSOLIZATION | - |
dc.subject | MICROORGANISMS | - |
dc.subject | ASSOCIATIONS | - |
dc.title | The level of submicron fungal fragments in homes with asthmatic children | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Seo, SungChul | - |
dc.contributor.affiliatedAuthor | Choung, Ji Tae | - |
dc.identifier.doi | 10.1016/j.envres.2014.02.015 | - |
dc.identifier.scopusid | 2-s2.0-84896530085 | - |
dc.identifier.wosid | 000336015100011 | - |
dc.identifier.bibliographicCitation | ENVIRONMENTAL RESEARCH, v.131, pp.71 - 76 | - |
dc.relation.isPartOf | ENVIRONMENTAL RESEARCH | - |
dc.citation.title | ENVIRONMENTAL RESEARCH | - |
dc.citation.volume | 131 | - |
dc.citation.startPage | 71 | - |
dc.citation.endPage | 76 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
dc.subject.keywordPlus | RELATIVE MOLDINESS INDEX | - |
dc.subject.keywordPlus | AIR-POLLUTION | - |
dc.subject.keywordPlus | ULTRAFINE PARTICLES | - |
dc.subject.keywordPlus | RESPIRATORY HEALTH | - |
dc.subject.keywordPlus | URBAN AIR | - |
dc.subject.keywordPlus | MOLD | - |
dc.subject.keywordPlus | EXPOSURE | - |
dc.subject.keywordPlus | AEROSOLIZATION | - |
dc.subject.keywordPlus | MICROORGANISMS | - |
dc.subject.keywordPlus | ASSOCIATIONS | - |
dc.subject.keywordAuthor | Bioaerosols | - |
dc.subject.keywordAuthor | Fine particles | - |
dc.subject.keywordAuthor | Fungal fragments | - |
dc.subject.keywordAuthor | Childhood asthmatics | - |
dc.subject.keywordAuthor | Mold exposure | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.