Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of the stepwise collimation method for the reduction of the patient dose in full spine radiography

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Boram-
dc.contributor.authorLee, Sunyoung-
dc.contributor.authorYang, Injeong-
dc.contributor.authorYoon, Myeonggeun-
dc.date.accessioned2021-09-05T09:23:16Z-
dc.date.available2021-09-05T09:23:16Z-
dc.date.created2021-06-15-
dc.date.issued2014-05-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/98725-
dc.description.abstractThe purpose of this study is to evaluate the dose reduction when using the stepwise collimation method for scoliosis patients undergoing full spine radiography. A Monte Carlo simulation was carried out to acquire dose vs. volume data for organs at risk (OAR) in the human body. While the effective doses in full spine radiography were reduced by 8, 15, 27 and 44% by using four different sizes of the collimation, the doses to the skin were reduced by 31, 44, 55 and 66%, indicating that the reduction of the dose to the skin is higher than that to organs inside the body. Although the reduction rates were low for the gonad, being 9, 14, 18 and 23%, there was more than a 30% reduction in the dose to the heart, suggesting that the dose reduction depends significantly on the location of the OARs in the human body. The reduction rate of the secondary cancer risk based on the excess absolute risk (EAR) varied from 0.6 to 3.4 per 10,000 persons, depending on the size of the collimation. Our results suggest that the stepwise collimation method in full spine radiography can effectively reduce the patient dose and the radiation-induced secondary cancer risk.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectSCOLIOSIS-
dc.titleEvaluation of the stepwise collimation method for the reduction of the patient dose in full spine radiography-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Myeonggeun-
dc.identifier.doi10.3938/jkps.64.1380-
dc.identifier.scopusid2-s2.0-84901261836-
dc.identifier.wosid000336314000024-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.64, no.9, pp.1380 - 1384-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume64-
dc.citation.number9-
dc.citation.startPage1380-
dc.citation.endPage1384-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001875739-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusSCOLIOSIS-
dc.subject.keywordAuthorSecondary cancer risk-
dc.subject.keywordAuthorSpine radiography-
dc.subject.keywordAuthorMonte Carlo simulation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE