Hydroxyapatite-coated magnesium implants with improved in vitro and in vivo biocorrosion, biocompatibility, and bone response
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Sae-Mi | - |
dc.contributor.author | Jo, Ji-Hoon | - |
dc.contributor.author | Lee, Sung-Mi | - |
dc.contributor.author | Kang, Min-Ho | - |
dc.contributor.author | Kim, Hyoun-Ee | - |
dc.contributor.author | Estrin, Yuri | - |
dc.contributor.author | Lee, Jong-Ho | - |
dc.contributor.author | Lee, Jung-Woo | - |
dc.contributor.author | Koh, Young-Hag | - |
dc.date.accessioned | 2021-09-05T11:35:02Z | - |
dc.date.available | 2021-09-05T11:35:02Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2014-02 | - |
dc.identifier.issn | 1549-3296 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/99351 | - |
dc.description.abstract | Magnesium and its alloys are candidate materials for biodegradable implants; however, excessively rapid corrosion behavior restricts their practical uses in biological systems. For such applications, surface modification is essential, and the use of anticorrosion coatings is considered as a promising avenue. In this study, we coated Mg with hydroxyapatite (HA) in an aqueous solution containing calcium and phosphate sources to improve its in vitro and in vivo biocorrosion resistance, biocompatibility and bone response. A layer of needle-shaped HA crystals was created uniformly on the Mg substrate even when the Mg sample had a complex shape of a screw. In addition, a dense HA-stratum between this layer and the Mg substrate was formed. This HA-coating layer remarkably reduced the corrosion rate of the Mg tested in a simulated body fluid. Moreover, the biological response, including cell attachment, proliferation and differentiation, of the HA-coated samples was enhanced considerably compared to samples without a coating layer. The preliminary in vivo experiments also showed that the biocorrosion of the Mg implant was significantly retarded by HA coating, which resulted in good mechanical stability. In addition, in the case of the HA-coated implants, biodegradation was mitigated, particularly over the first 6 weeks of implantation. This considerably promoted bone growth at the interface between the implant and bone. These results confirmed that HA-coated Mg is a promising material for biomedical implant applications. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 429-441, 2014. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | SIMULATED BODY-FLUID | - |
dc.subject | Y-ZN ALLOYS | - |
dc.subject | CORROSION-RESISTANCE | - |
dc.subject | BIOMEDICAL APPLICATIONS | - |
dc.subject | SURFACE MODIFICATION | - |
dc.subject | CALCIUM-PHOSPHATE | - |
dc.subject | PURE MG | - |
dc.subject | BIOMATERIALS | - |
dc.subject | BEHAVIOR | - |
dc.subject | BIODEGRADATION | - |
dc.title | Hydroxyapatite-coated magnesium implants with improved in vitro and in vivo biocorrosion, biocompatibility, and bone response | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Koh, Young-Hag | - |
dc.identifier.doi | 10.1002/jbm.a.34718 | - |
dc.identifier.scopusid | 2-s2.0-84890569435 | - |
dc.identifier.wosid | 000328246100015 | - |
dc.identifier.bibliographicCitation | JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, v.102, no.2, pp.429 - 441 | - |
dc.relation.isPartOf | JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | - |
dc.citation.title | JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | - |
dc.citation.volume | 102 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 429 | - |
dc.citation.endPage | 441 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Biomaterials | - |
dc.subject.keywordPlus | SIMULATED BODY-FLUID | - |
dc.subject.keywordPlus | Y-ZN ALLOYS | - |
dc.subject.keywordPlus | CORROSION-RESISTANCE | - |
dc.subject.keywordPlus | BIOMEDICAL APPLICATIONS | - |
dc.subject.keywordPlus | SURFACE MODIFICATION | - |
dc.subject.keywordPlus | CALCIUM-PHOSPHATE | - |
dc.subject.keywordPlus | PURE MG | - |
dc.subject.keywordPlus | BIOMATERIALS | - |
dc.subject.keywordPlus | BEHAVIOR | - |
dc.subject.keywordPlus | BIODEGRADATION | - |
dc.subject.keywordAuthor | magnesium | - |
dc.subject.keywordAuthor | biodegradation | - |
dc.subject.keywordAuthor | hydroxyapatite coating | - |
dc.subject.keywordAuthor | corrosion | - |
dc.subject.keywordAuthor | biocompatibility | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.