The AC loss of an HTS transformer by 2D and 3D numerical calculation

  • Choi, S.
  • Park, S. H.
  • Lee, S. Y.
  • Kim, W.
  • Park, C.
  • ... Lee, H.
  • 외 3명
Citations

WEB OF SCIENCE

4
Citations

SCOPUS

7

초록

For the design of a high temperature superconductor (HTS) power transformer the AC loss is a critical issue because the energy is dissipated as heat in the low temperature. It is necessary to study the AC losses theoretically and experimentally. For the analysis of AC losses in an HTS power transformer, two-dimensional numerical analysis has been carried out until now. However, AC losses which are calculated by using two-dimensional numerical analysis differ from those using three-dimensional numerical analysis because the geometry of the HTS transformer is not symmetric. AC losses of a 1 MVA-single-phase HTS transformer were calculated using both two-dimensional and three-dimensional numerical analysis. To prove the effectiveness of the calculations, the numerical results were compared with the measured results for a transformer fabricated using Bi2Sr2CaCu2O8+delta tapes in 2004. (C) 2009 Elsevier B.V. All rights reserved.

키워드

AC lossHTS transformerNumerical analysis
제목
The AC loss of an HTS transformer by 2D and 3D numerical calculation
저자
Choi, S.Park, S. H.Lee, S. Y.Kim, W.Park, C.Song, J. B.Lee, H.Choi, K.Hahn, S.
DOI
10.1016/j.physc.2009.05.254
발행일
2009-08
유형
Article; Proceedings Paper
저널명
Physica C: Superconductivity and its Applications
469
15-20
페이지