Ultrasonographic Evaluation of Needle Electromyography Insertion Into the Tibialis Posterior Using a Posterior Approach

Citations

WEB OF SCIENCE

12
Citations

SCOPUS

15

초록

Objective: To estimate the safety window for needle insertion in the posterior approach to the tibialis posterior by ultrasonography, particularly in a clinical setting. Design: Cross-sectional study. Setting: University hospital. Participants: Healthy volunteers (108 legs, from 22 men and 32 women). Interventions: Not applicable. Main Outcome Measures: Distance between the tibia and neurovascular bundles in the posterior aspect of the tibia on a transverse ultrasonographic scan. Results: The safety window at the midpoint was significantly larger than the upper third (0.62-2.16cm, average 1.47 +/- 0.38cm vs 0.51-1.62cm, average 1.16 +/- 0.31cm). The depth at the midpoint was significantly more shallow than the upper third (1.57-3.16cm, average 2.31 +/- 0.34cm vs 1.76-3.66cm, average 2.52 +/- 0.38cm). Body weight, height, tibial length, and leg circumference showed positive correlation with the safety window at both points. Conclusions: The midpoint may be more favorable than the upper third for needle insertion to the tibialis posterior with a posterior approach.

키워드

ElectromyographyRehabilitationUltrasonographyELECTRODE INSERTIONANTERIOR
제목
Ultrasonographic Evaluation of Needle Electromyography Insertion Into the Tibialis Posterior Using a Posterior Approach
저자
Won, Sun JaeKim, Jun YeonYoon, Joon ShikKim, Sei Joo
DOI
10.1016/j.apmr.2011.05.013
발행일
2011-11
유형
Article
저널명
Archives of Physical Medicine and Rehabilitation
92
11
페이지
1921 ~ 1923