상세 보기
초록
A digital technique is adopted to calibrate the current mismatch of the charge pump (CP) in phase-locked loops. A 2 GHz charge pump PLL (CPPLL) is used to justify the proposed calibration technique. The proposed digital calibration technique is implemented simply using a counter. The proposed calibration technique reduces the calibration time by up to a maximum of 50% compared other with techniques. Also by using a dual-mode CP, good current matching characteristics can be achieved to compensate 0.5μA current mismatch in CP. It was designed in a standard 0.13μm CMOS technology. The maximum calibration time is 33.6μs and the average power is 18.38mW with 1.5V power supply and effective area is 0.1804mm2.
키워드
Charge pump(CP) mismatch; Digital calibration; Charge pump phase-locked loop(CPPLL)
- 제목
- 카운터 기반 디지털 보상 기법을 이용한 위상 고정 루프
- 제목 (타언어)
- Phase-Locked Loops using Digital Calibration Technique with counter
- 저자
- 정찬희; Ammar Abdullah; 이관주; 김훈기; 김수원
- 발행일
- 2011
- 저널명
- 전기학회논문지
- 권
- 60
- 호
- 2
- 페이지
- 320 ~ 324