Reliability of the intelligent stretching device for ankle stiffness measurements in healthy individuals

  • Sung, P.S.
  • Baek, J.-Y.
  • Kim, Y.H.
Citations

SCOPUS

10

초록

Background: A number of devices have been developed to measure joint stiffness. This study investigated the reliability of the Intelligent (Intel) stretch device to measure bilateral ankle joint stiffness during passive range of motion (ROM). Methods: The reliability of the device was investigated based on torque and angle by establishing the consistency of measurements between examiners on different testing days. In addition, demographic variables were analyzed to investigate the degree of stiffness. Forty-six gender-matched subjects completed the test. Results: The reliability ICC2,1 coefficient of ankle stiffness between-day for both examiners was 0.77 for the right ankle and 0.76 for the left ankle with a 0.05 standard error of measurement (SEM) for ankle stiffness for the right side and 0.04 for the left side. The ICC values of the two examiners were also high based on Chronbach's alpha (0.87 and 0.86). Among the demographic variables, gender (F=35.25, p=0.001) and body weight (F=23.55, p=0.001) were the most important factors in determining ankle joint stiffness. Discussion: The results of this study indicated that dorsiflexion and plantarflexion measurements obtained by the Intel stretch device are reproducible and consistent. In addition, ankle stiffness was significantly different based on gender and body weight to develop and/or maintain ankle function. These results may help to identify ankle stiffness factors that will lead to more efficient rehabilitation programs and injury prevention strategies. © 2010 Elsevier Ltd.

키워드

Ankle jointDeviceMeasurementReliabilityStiffnessStretchTorqueadultagedankle stiffnessarticlebody weightcontrolled studydemographyequipment designfemalehumanhuman experimentintelligent streching devicejoint examinationjoint stiffnessmalemeasurement errornormal humanorthopedic equipmentpriority journalreliabilitysex differenceAdultAnkle JointBody WeightDecision Making, Computer-AssistedElectromyographyFeedbackFemaleHumansMaleMiddle AgedPhysical Therapy ModalitiesRange of Motion, ArticularRegression AnalysisReproducibility of ResultsSex FactorsTorque
제목
Reliability of the intelligent stretching device for ankle stiffness measurements in healthy individuals
저자
Sung, P.S.Baek, J.-Y.Kim, Y.H.
DOI
10.1016/j.foot.2010.09.005
발행일
2010
유형
Article
저널명
Foot
20
4
페이지
126 ~ 132