상세 보기
Reoperative Surgical Stabilization of a Painful Nonunited Rib Fracture Using Bone Grafting and a Metal Plate
- Cho, Yang Hyun;
- Kim, Hyun Koo;
- Kang, Du-Young;
- Choi, Young Ho
Citations
WEB OF SCIENCE
14Citations
SCOPUS
16초록
We report a case of a nonunited sixth rib in a patient with multiple rib fractures who underwent internal fixation using a wire and Judet strut 3 times. During the following 3 years, the patient continued to complain of pain and instability. At surgery, a pseudarthrosis between the ends of the sixth rib was excised. A longitudinal gutter crossing the fracture site was fashioned and splinted with an inlay block of cancellous bone grafted from the iliac crest; stabilization was accomplished with a reconstruction plate and screws. The following 2 years of follow-up demonstrated no instability or pain.
키워드
rib; fracture; nonunion; bone graft
- 제목
- Reoperative Surgical Stabilization of a Painful Nonunited Rib Fracture Using Bone Grafting and a Metal Plate
- 저자
- Cho, Yang Hyun; Kim, Hyun Koo; Kang, Du-Young; Choi, Young Ho
- 발행일
- 2009-09
- 유형
- Article
- 권
- 23
- 호
- 8
- 페이지
- 605 ~ 606