Sample delivery using viscous media, a syringe andasyringe pump for serial crystallography

  • Park, Suk-Youl
  • Nam, Ki Hyun
Citations

WEB OF SCIENCE

31
Citations

SCOPUS

31

초록

Sample delivery using injectors is widely used in serial crystallography (SX) and has significantly contributed to the determination of crystal structures at room temperature. However, sophisticated injector nozzle fabrication methods and sample delivery operations have made it difficult for ordinary users to access the SX research. Herein, a simple and easily accessible sample delivery method for SX experiments is introduced, that uses a viscous medium, commercially available syringe and syringe pump. The syringe containing the lysozyme crystals embedded in lipidic cubic phase (LCP) or polyacrylamide (PAM) delivery media was connected to a needle having an inner diameter of 168 mu m, after which it was installed on a syringe pump. By driving the syringe pump, the syringe plunger was pushed and the crystal sample was delivered to the X-ray beam position in a stable manner. Using this system, the room-temperature crystal structures of lysozyme embedded in LCP and PAM at 1.56 angstrom and 1.75 angstrom, respectively, were determined. This straightforward syringe pump-based sample delivery system can be utilized in SX.

키워드

serial crystallographysample deliverysyringe pumpsviscous medialipidic cubic phasepolyacrylamide
제목
Sample delivery using viscous media, a syringe andasyringe pump for serial crystallography
저자
Park, Suk-YoulNam, Ki Hyun
DOI
10.1107/S160057751900897X
발행일
2019-09
유형
Article
저널명
Journal of Synchrotron Radiation
26
페이지
1815 ~ 1819