Electrical Testing for Detection and Classification of Open Damper Bar and Shorted Field Winding Failures in Wound Field Synchronous Motors

  • Shaikh, Muhammad Faizan
  • Park, Jongsan
  • Park, Yonghyun
  • Lee, Sang Bin
  • Antonino-Daviu, Jose A.
Citations

WEB OF SCIENCE

11
Citations

SCOPUS

14

초록

Broken damper bars and shorted field winding turns degrade the starting and running performance of industrial wound field synchronous motors (WFSMs), and can lead to a forced outage of the motor and driven process. Testing of WFSM rotor windings mainly relies on offline tests, which cannot be performed frequently and are known to lack reliability. Shorted turns in the field winding can be detected online from the airgap flux measurement, but require a sensor to be installed on the stator bore. In this article, new test methods for detecting and classifying damper and field winding faults based on electrical signals are proposed. The proposed methods can provide remote testing at motor standstill and during the motor starting transient without disassembling the motor. Test results on a 30 kW, salient pole WFSM show that both test methods can provide reliable detection and classification of damper and field winding faults.

키워드

RotorsWindingsShock absorbersSynchronous motorsBarsSynchronizationCircuit faultsCondition monitoringdamper barfault diagnosticsfield windingmotor testingspectral analysiswound field synchronous motorFAULTS
제목
Electrical Testing for Detection and Classification of Open Damper Bar and Shorted Field Winding Failures in Wound Field Synchronous Motors
저자
Shaikh, Muhammad FaizanPark, JongsanPark, YonghyunLee, Sang BinAntonino-Daviu, Jose A.
DOI
10.1109/TIA.2022.3167017
발행일
2022-07
유형
Article
저널명
IEEE Transactions on Industry Applications
58
4
페이지
4532 ~ 4541